2017
DOI: 10.3390/en10071046
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Power Transmission of Offshore Wind Power Using a VSC-HVdc Interconnection

Abstract: High-voltage dc transmission based on voltage-source converter (VSC-HVdc) is quickly increasing its power rating, and it can be the most appropriate link for the connection of offshore wind farms (OWFs) to the grid in many locations. This paper presents a steady-state operation model to calculate the optimal power transmission of an OWF connected to the grid through a VSC-HVdc link. The wind turbines are based on doubly fed induction generators (DFIGs), and a detailed model of the internal OWF grid is consider… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Wind energy was assumed to be extracted by one Vestas V90 3 MW wind turbine. It is one of the most widely used offshore wind turbines in the world, and its power curve has been provided by the manufacturer (Figure 3) [33,34]. The Vestas V90 3 MW has a hub height of 80 m, diameter of 90 m, cut-in wind speed of 4 m/s, rated wind speed of 16 m/s, cut-out wind speed of 25 m/s, and restart (cut-back-in) wind speed of 20 m/s [54].…”
Section: Methodsmentioning
confidence: 99%
“…Wind energy was assumed to be extracted by one Vestas V90 3 MW wind turbine. It is one of the most widely used offshore wind turbines in the world, and its power curve has been provided by the manufacturer (Figure 3) [33,34]. The Vestas V90 3 MW has a hub height of 80 m, diameter of 90 m, cut-in wind speed of 4 m/s, rated wind speed of 16 m/s, cut-out wind speed of 25 m/s, and restart (cut-back-in) wind speed of 20 m/s [54].…”
Section: Methodsmentioning
confidence: 99%
“…The methodology for the reactive power incorporation and impact evaluation on the performance of an HVAC export cable system is also validated in [7], and the comparisons between AC and DC are noted in [8]. Alternatively, the advantages of pairing a DFIG-based (doubly-fed induction generator) offshore wind turbine generator (WTG) with VSC-based HVDC to improve the overall performance of the export system are noted [9] while the wide-scale deployment of said technologies for the growing large-scale OWF is once more validated in [10].…”
Section: Literature Reviewmentioning
confidence: 99%
“…2 represents VSC-HVDC transmission system, whose dc link voltage is regulated by one converter and active power flow by the other [27]. whose amplitude and frequency are constant, the current and voltage harmonics for converters are negligible, the dc components have no ripples and, the internal losses of converters are negligible [28]. Therefore, equivalent representation of Fig.…”
Section: Vsc-hvdc Systemmentioning
confidence: 99%