2022
DOI: 10.1109/tpwrd.2021.3108760
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Protection Coordination for Inverter Dominated Islanded Microgrids Considering N-1 Contingency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 28 publications
0
15
0
Order By: Relevance
“…š‘‡š·š‘† is the time dial setting of the relay, š¼ š‘ is the pickup current, and š¼ š‘“ is the fault current measured by the DOCR. It is worth mentioning that OPC studies target short-circuit faults that result in overcurrent, which typically occur due to relatively low resistance faults [21,26]. Thus, this paper does not focus on high-impedance faults (HIFs).…”
Section: B Docr's Optimal Settingsmentioning
confidence: 99%
See 1 more Smart Citation
“…š‘‡š·š‘† is the time dial setting of the relay, š¼ š‘ is the pickup current, and š¼ š‘“ is the fault current measured by the DOCR. It is worth mentioning that OPC studies target short-circuit faults that result in overcurrent, which typically occur due to relatively low resistance faults [21,26]. Thus, this paper does not focus on high-impedance faults (HIFs).…”
Section: B Docr's Optimal Settingsmentioning
confidence: 99%
“…Another OPC solution is implemented for microgrids protected by dual-setting overcurrent relays that consist of IIDGs and energy storage systems [25]. In [26], the OPC is formulated to consider different microgrid topologies during N-1 contingencies. The OPC problem for distribution networks with IIDGs is formulated considering user-defined DOCR characteristics [27].…”
Section: Introductionmentioning
confidence: 99%
“…In some studies, it has been used to reduce consumer downtime in the event of Nāˆ’1 or Nāˆ’k events. However, since SDGs cannot rapidly reduce their output power in the event of a fault such as a short circuit, they inject significant fault current into the fault location [11][12][13][14][15][16]. Therefore, the existing protection coordination in the network will be deteriorated.…”
Section: Yes Sca+gwomentioning
confidence: 99%
“…To address this, optimal planning of FCL or SFCL has been suggested in some studies such as [10,11]. Also, the use of DOCR to improve the protection coordination conditions in the network with SDG is suggested [12,[14][15]. These cases require additional payment for the installation of these elements.…”
Section: Yes Sca+gwomentioning
confidence: 99%
See 1 more Smart Citation