IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society 2018
DOI: 10.1109/iecon.2018.8591686
|View full text |Cite
|
Sign up to set email alerts
|

Optimal sizing of a power electronic traction transformer for railway applications

Abstract: Many works are dedicated to power electronic transformers in order to replace line frequency transformers. These new converters offer many degrees of freedom to the designer (switching frequency, magnetic material, rated voltage for switches. . . ). This paper presents a methodology to optimize the sizing of such power converters in order to compare different topologies for a given application. The proposed procedure maximises the efficiency of the converter under a limited volume. In this paper, the methodolo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…In order to obtain noiseless operation of MV drives, multi-level topologies are used with the use of low-voltage (1.2 kV or 1.7 kV) SiC transistors. Among others, power electronic traction transformers (PETTs), built with power electronic building blocks (PEBB) with built-in input/output isolation, realized by small size and high power density medium frequency transformers (MFT) are of particular interest [13][14][15][16][17][18][19].…”
Section: Devicementioning
confidence: 99%
See 3 more Smart Citations
“…In order to obtain noiseless operation of MV drives, multi-level topologies are used with the use of low-voltage (1.2 kV or 1.7 kV) SiC transistors. Among others, power electronic traction transformers (PETTs), built with power electronic building blocks (PEBB) with built-in input/output isolation, realized by small size and high power density medium frequency transformers (MFT) are of particular interest [13][14][15][16][17][18][19].…”
Section: Devicementioning
confidence: 99%
“…So far, the primary purpose of SiC-based PETTs were primarily traction drives powered from the AC lines: 15 kV/16.7 Hz [13,14,18,19] and 25 kV/50 Hz [15][16][17]. AC powered locomotives and EMUs have a complex and voluminous conversion chain including a step-down transformer, rectifier, low-frequency filter and traction inverter.…”
Section: Devicementioning
confidence: 99%
See 2 more Smart Citations
“…The ferrite also offers low cost in terms of material and transformer assembly. In [32], the ferrite core MFT was considered for an optimized dc-dc converter operating at a few kHz. Finally, the ferrite seems as a good candidate for the short term industrialization of the high power three-phase MFT.…”
Section: Introductionmentioning
confidence: 99%