Optimal Tuning of the Current Loop for Dual-Loop Controlled Grid-Forming Converters Based on Active Damping Optimization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…The effect of the resonant term could be disregarded for frequencies that are not near the fundamental frequency [20]. Therefore, the loop gain could be simplified by just considering the proportional term as (6), for analyzing the system stability in the range of medium and high frequencies.…”
Section: System Description and Stability Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…The effect of the resonant term could be disregarded for frequencies that are not near the fundamental frequency [20]. Therefore, the loop gain could be simplified by just considering the proportional term as (6), for analyzing the system stability in the range of medium and high frequencies.…”
Section: System Description and Stability Analysismentioning
confidence: 99%
“…s ω that comes from the delay in (6). In other words, the introduced negative phase of the delay helps the single-loop GFIs to work stably when f r > f s /3.…”
Section: System Description and Stability Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, many different current control loop solutions have been developed, most of which are based on symmetrical component extraction [11], [16], discussing tuning of parameters [17], as well as dynamic and tracking performance to directly control the injected current [18]. Furthermore, active and reactive power production and utilisation have been extensively analysed in recent years.…”
Section: B Control Structuresmentioning
confidence: 99%
“…The VSC generally adopts voltage and current dual-loop Proportional Integral (PI) control, which can theoretically achieve a zero steady-state error tracking effect [14]. However, the PI control is sensitive to the uncertainty of the system parameters and external disturbances, and its tuning process is tedious [15], which will affect the stability of the DC bus voltage. To effectively regulate the DC bus voltage, the current inner loop robust control in dualloop control has been studied in many kinds of literature.…”
Section: Introductionmentioning