2018
DOI: 10.5114/wo.2018.81751
|View full text |Cite
|
Sign up to set email alerts
|

Optimisation of [11C]-choline synthesis

Abstract: The importance of [11C]-choline as a PET/CT marker has been extensively described, although its production presents considerable technical difficulties. The main ones are short half-lives and the occurrence of dimethylformamide (DMF) as a residual solvent. While the losses resulting from the radionuclide decay can be minimised by shortening the duration of the process, the best solution for reducing the content of DMF is its elimination from the reaction environment. In the current work two methods are compare… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…911−918 Excellent yields (RCY > 80% at EOB) are always obtained in a short synthesis time, allowing reliable production of multiple doses and several batches per day. 919 In addition, Trasis offers commercially available cassette kits and ready-touse consumables for fully automated preparation of [ 11 C]choline on the Trasis AllinOne synthesizer, further facilitating GMP implementation. The most simple, efficient, and reliable automated method for [ 11 C]choline routine clinical production was described in detail, and the quality control procedures by Hockley, Shao, et al 848,851 Typical RCYs >60% at EOB in a total synthesis time of 20 min.…”
Section: Other Compoundsmentioning
confidence: 99%
See 1 more Smart Citation
“…911−918 Excellent yields (RCY > 80% at EOB) are always obtained in a short synthesis time, allowing reliable production of multiple doses and several batches per day. 919 In addition, Trasis offers commercially available cassette kits and ready-touse consumables for fully automated preparation of [ 11 C]choline on the Trasis AllinOne synthesizer, further facilitating GMP implementation. The most simple, efficient, and reliable automated method for [ 11 C]choline routine clinical production was described in detail, and the quality control procedures by Hockley, Shao, et al 848,851 Typical RCYs >60% at EOB in a total synthesis time of 20 min.…”
Section: Other Compoundsmentioning
confidence: 99%
“…There was no A m release limit for [ 11 C]­choline. Several synthetic approaches have been described in the literature, and different automated production methods and modules for clinical production. Excellent yields (RCY > 80% at EOB) are always obtained in a short synthesis time, allowing reliable production of multiple doses and several batches per day . In addition, Trasis offers commercially available cassette kits and ready-to-use consumables for fully automated preparation of [ 11 C]­choline on the Trasis AllinOne synthesizer, further facilitating GMP implementation.…”
Section: Other Compoundsmentioning
confidence: 99%