Optimization of a Flow Injection Differential Potentiometric System with Two Identical Electrodes for the Determination of Calcium Ion in Water With Improved Sensitivity

Abstract: An experimental optimization by the modified simplex method of a flow injection analysis (FIA) system for the differential potentiometric determination of calcium ion in water is reported. The performances of the optimized system and of an equivalent conventional potentiometric FIA system are compared. The most important features of the proposed system are a substantial increase in sensitivity (from about 28 to about 50 mV per decade) in the linear response range (10 24 -10 22 mol l 21 in both cases) and bette… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
6
0
2

Year Published

1998
1998
2005
2005

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 21 publications
1
6
0
2
Order By: Relevance
“…The system described in this paper uses electrodes selective to calcium and chloride placed in series, to allow the simultaneous determination of both species in natural waters. As in the previous case, 8 the shape of the signal was found to depend on the geometric and hydrodynamic parameters of the system, owing to the comparatively slow response of the calcium electrode. Therefore, the system had to be optimized to find the best conditions in which the electrodes work alternatively as indicator and reference electrodes.…”
supporting
confidence: 66%
See 2 more Smart Citations
“…The system described in this paper uses electrodes selective to calcium and chloride placed in series, to allow the simultaneous determination of both species in natural waters. As in the previous case, 8 the shape of the signal was found to depend on the geometric and hydrodynamic parameters of the system, owing to the comparatively slow response of the calcium electrode. Therefore, the system had to be optimized to find the best conditions in which the electrodes work alternatively as indicator and reference electrodes.…”
supporting
confidence: 66%
“…Flow injection analysis (FIA) with potentiometric detection allows the assembly of devices in which both electrodes contribute to the signal, thus providing full utilization of the capacity of the potentiometric cell to generate information. [1][2][3][4][5][6][7][8] We recently described a system where two calcium ion selective electrodes (ISEs) are placed in series in the manifold, one connected to the reference input and the other to the electrode input of one voltmeter. 8 If the flow and manifold parameters are adequately chosen, the second ISE keeps a constant potential (fixed by the background concentration in the carrier solution of the species to which this ISE is sensible) while the sample is flowing through the first electrode and provides signal, and vice versa.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…O primeiro sistema FIA com detecção multiparamétrica deve-se a Hansen 127 , que incorporou, em série, um eléctrodo sensível a cálcio e outro de pH para detecção simultânea dos respectivos iões. Este procedimento pode ser atingido utilizando-se vários 14,42,56,67,69,97,109,127,152,160,174,175,177,182,184,196,198,203,207,220,224,226,273,301 , ou um só detector, com a ajuda de diferentes configurações FIA 331 . As montagens para determinações multiparamétricas podem ser baseadas na colocação de detectores em série, desde que o primeiro detector não seja destrutivo da amostra, ou na divisão de fluxo após a injecção da mesma.…”
Section: Figura 4 Distribuição Das áReas De Aplicação Dos Sistemas Funclassified
“…A utilização frequente destes sistemas, nos quais numa mesma análise se procede à monitorização de dois ou mais parâmetros, tem sido muito explorada, particularmente nesta última década, sobretudo porque, dada a utilização de unidades de configuração tubular, o fluxo de amostra mantém as suas características hidrodinâmicas inalteradas. Encontramse descritos inúmeros sistemas de fluxo empregando dois ou mais detectores potenciométricos 14,42,56,67,69,97,109,127,152,160,174,175,177,182,184,196,198,203,207,220,224,226,273,301 , mas também dois tipos distintos de processos de detecção 7,21,25,34,73,75,79,80,120,141,152,156,187,189,197,219,232,233,287,290,304,312,318 . Como exemplos destacam-se,...…”
Section: Figura 4 Distribuição Das áReas De Aplicação Dos Sistemas Funclassified