2015
DOI: 10.1002/rcm.7389
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of a large‐volume injection method for compound‐specific isotope analysis of polycyclic aromatic compounds at trace concentrations

Abstract: LVI with PTV injector cooling allows for the isotopic analysis of volatile and semi-volatile PAHs at trace concentrations, thus considerably expanding the applicability of CSIA in environmental studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 49 publications
0
4
0
Order By: Relevance
“…In case ME-CSIA data cannot solely prove in situ biodegradation, additional methods should be employed as geochemical approaches, metabolite analyses, in situ microcosms or expression analyses of functional genes [3,48]. For environmental samples containing low concentrated, almost water insoluble hydrocarbons, new techniques have been recently described for extraction and carbon and/or hydrogen isotope analysis, allowing, for example, measuring PAHs in the sub-ng L À1 range [49][50][51]. Similar approaches have been done for the isotopic analysis of micropollutants [12].…”
Section: Discussionmentioning
confidence: 99%
“…In case ME-CSIA data cannot solely prove in situ biodegradation, additional methods should be employed as geochemical approaches, metabolite analyses, in situ microcosms or expression analyses of functional genes [3,48]. For environmental samples containing low concentrated, almost water insoluble hydrocarbons, new techniques have been recently described for extraction and carbon and/or hydrogen isotope analysis, allowing, for example, measuring PAHs in the sub-ng L À1 range [49][50][51]. Similar approaches have been done for the isotopic analysis of micropollutants [12].…”
Section: Discussionmentioning
confidence: 99%
“…Accordingly, different nonfractionating extraction strategies have to be considered such as solid-phase extractions or the use of semipermeable membrane devices . Recently described methods for sensitive carbon and/or hydrogen isotope analysis of PAHs may offer chances to isotopically analyze PAHs up to the ng L –1 range. Further limitations of CSIA can result from mixing effects of different aquifer zones during sampling of contaminated groundwater; especially at the fringe of the plume, reactive zones often occur at fine spatial scale . As a rule of thumb, samples for CSIA or other analyses should be taken from multilevel sampling wells located in the source and the fringe of the plume to prevent any mixing effects.…”
Section: Discussionmentioning
confidence: 99%
“…According to reports, a programmable temperature vaporizer (PTV) enables the injection of larger volumes when the expected levels are very low, and protects thermolabile compounds by progressively heating and vaporizing them. 119,120 Compared with traditional GC method, the recovery of GC-MS with PTV and an automatic sampler was signicantly improved; this was due to the reduced analyte loss during the sample preparation step. 121…”
Section: Gas Chromatography-mass Spectrometry (Gc-ms)mentioning