2018 21st International Conference on Electrical Machines and Systems (ICEMS) 2018
DOI: 10.23919/icems.2018.8549294
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Current Breaker and Fault Current Limiter in DC Micro-Grid Based on Faulty Transient Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…The use in fault detection and fault location can be found in [26]. While, the use for the selection of parameters of isolation devices can be found in [27]. The control systems in converters will keep their normal control strategies during the period from fault occurrence to fault detection.…”
Section: Enable Isolation Devices Normal Operationmentioning
confidence: 99%
See 1 more Smart Citation
“…The use in fault detection and fault location can be found in [26]. While, the use for the selection of parameters of isolation devices can be found in [27]. The control systems in converters will keep their normal control strategies during the period from fault occurrence to fault detection.…”
Section: Enable Isolation Devices Normal Operationmentioning
confidence: 99%
“…According to [27], there are only two kinds of variables (nodes voltages and lines currents) in system structures of DC microgrids. And the difference expressions of nodes voltages and lines currents can be expressed as: (…”
Section: Transient Analysis Of Faulty DC Microgridmentioning
confidence: 99%
“…According to [26], the state variables in DC microgrid mainly include nodes voltage and lines current. Assuming that there are N nodes and m lines in DC microgrid, the nodes voltage and lines current can be expressed as:…”
Section: Validation and Comparison Of Vsc Modelmentioning
confidence: 99%
“…The parameters configuration of protection devices in DC microgrid is one of the most typical application for the transient modeling of DC microgrid. Moreover, CB and fault current limiter (FCL) are two mainly protection devices in faulty DC microgrid [26].Thus, in order to verify the value of the transient modeling method proposed in this paper, the method is used to analyze the transient characteristics of faulty DC microgrid under different parameters of CB and FCL. And then, the parameters configuration of protection devices can be achieved based on the transient characteristics of faulty DC microgrid.…”
Section: Application Of DC Microgrid Transient Modelmentioning
confidence: 99%
“…For dc feeders the speed of fault location becomes critical, typically 10's of microseconds, due to the following reasons. 1) In response to a fault, current in dc circuits rises in a matter of tens of microseconds [2], without having a natural current zero. If the fault current crosses the breaking limit of the controlling circuit breaker, it can not be interrupted.…”
Section: Introductionmentioning
confidence: 99%