2022 IEEE/SICE International Symposium on System Integration (SII) 2022
DOI: 10.1109/sii52469.2022.9708756
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Detector Movement Algorithm Using Decision Trees Analysis for Radiation Source Identification Based on 4π Gamma Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 7 publications
1
6
0
Order By: Relevance
“…For rapidly identifying radiation sources using 4π gamma imaging, the images should be obtained from multiple positions that are suitable for obtaining the intensity and position information of the sources. In a previous study, we developed a detector movement algorithm for a single radiation source [13]. The first priority in the algorithm is that the detector is moved to the direction with the highest intensity in the 4π gamma image, and the second one is that the detector is moved away from the direction with the highest intensity in the image and toward the direction with the next-higher intensity in the image.…”
Section: Investigation Of Path-planning System Using An Integrated Si...mentioning
confidence: 99%
See 4 more Smart Citations
“…For rapidly identifying radiation sources using 4π gamma imaging, the images should be obtained from multiple positions that are suitable for obtaining the intensity and position information of the sources. In a previous study, we developed a detector movement algorithm for a single radiation source [13]. The first priority in the algorithm is that the detector is moved to the direction with the highest intensity in the 4π gamma image, and the second one is that the detector is moved away from the direction with the highest intensity in the image and toward the direction with the next-higher intensity in the image.…”
Section: Investigation Of Path-planning System Using An Integrated Si...mentioning
confidence: 99%
“…In this study, we investigated a path-planning system for detector movement. An integrated simulation model [13] that estimates the location and intensity of a single gamma source from gamma images at arbitrary positions around the source was used to develop the path-planning system. To obtain gamma images in the simulation, a 3D multipixel array CdTe detector was assumed as a 4π gamma imager.…”
Section: Investigation Of Path-planning System Using An Integrated Si...mentioning
confidence: 99%
See 3 more Smart Citations