Objective. The aim of this work was to determine heterogeneous correction factors h[fclin,fref QclinQref ]m,w det to validate absorbed dose-to-medium Dm,fclin m,Qclin calculation algorithms from detector readings. The impact of detector orientation perpendicular and parallel to the beam central axis on the correction factors was also investigated. Approach. The h[fclin,fref QclinQref ]m,w det factors were calculated for four types of detectors (PTW PinPoint T31016, PTW microDiamond T60016, PTW microSilicon T60023 and EBT3 film) placed in different media (cortical bone, lung, Teflon, adipose tissue and RW3) for the 6 MV energy beam with a 10x10 cm2 field size. These corrections were then applied to the detector measurements performed at different depths in heterogeneous phantoms. Main results. The h[fclin,fref QclinQref ]m,w det factors mainly depended on the media and slightly on the type of detector. Considering all detectors, the largest corrections were found in high-density media with values ranging from 0.911 to 0.934 in cortical bone. For comparison, the corrections in other media were closer to unity with values from 0.966 (lung and RW3) to 0.991 (adipose tissue). Except for the PinPoint T31016, detector orientation-dependence was observed especially in high-density media. A good agreement (≤ 1.5%) was found between Dm,fclin m,Qclin calculations and the detector readings corrected with the h[fclin,fref QclinQref ]m,w det factor for all studied heterogeneous phantoms. Significance This paper could serve as an initial guideline for medical physicists involved in the validation of the advanced type-b dose calculation algorithms reporting Dm,fclin m,Qclin . To our knowledge, this is the first study to assess the impact of the orientation of different detectors in heterogeneous media. The orientation dependence of the detector response observed in water may not reflect what is observed in heterogeneous media, especially in high-density media. The knowledge of the h[fclin,fref QclinQref ]m,w det factors becomes mandatory for accurate interpretation of detector readings and comparisons with Dm,fclin m,Qclin calculations.
Objective. The aim of this work was to determine heterogeneous correction factors h[fclin,fref QclinQref ]m,w det to validate absorbed dose-to-medium Dm,fclin m,Qclin calculation algorithms from detector readings. The impact of detector orientation perpendicular and parallel to the beam central axis on the correction factors was also investigated. Approach. The h[fclin,fref QclinQref ]m,w det factors were calculated for four types of detectors (PTW PinPoint T31016, PTW microDiamond T60016, PTW microSilicon T60023 and EBT3 film) placed in different media (cortical bone, lung, Teflon, adipose tissue and RW3) for the 6 MV energy beam with a 10x10 cm2 field size. These corrections were then applied to the detector measurements performed at different depths in heterogeneous phantoms. Main results. The h[fclin,fref QclinQref ]m,w det factors mainly depended on the media and slightly on the type of detector. Considering all detectors, the largest corrections were found in high-density media with values ranging from 0.911 to 0.934 in cortical bone. For comparison, the corrections in other media were closer to unity with values from 0.966 (lung and RW3) to 0.991 (adipose tissue). Except for the PinPoint T31016, detector orientation-dependence was observed especially in high-density media. A good agreement (≤ 1.5%) was found between Dm,fclin m,Qclin calculations and the detector readings corrected with the h[fclin,fref QclinQref ]m,w det factor for all studied heterogeneous phantoms. Significance This paper could serve as an initial guideline for medical physicists involved in the validation of the advanced type-b dose calculation algorithms reporting Dm,fclin m,Qclin . To our knowledge, this is the first study to assess the impact of the orientation of different detectors in heterogeneous media. The orientation dependence of the detector response observed in water may not reflect what is observed in heterogeneous media, especially in high-density media. The knowledge of the h[fclin,fref QclinQref ]m,w det factors becomes mandatory for accurate interpretation of detector readings and comparisons with Dm,fclin m,Qclin calculations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.