2020
DOI: 10.1007/s00216-020-02743-0
|View full text |Cite|
|
Sign up to set email alerts
|

Optimized hidden target screening for very polar molecules in surface waters including a compound database inquiry

Abstract: Highly polar trace organic compounds, which are persistent, mobile, and toxic (PMT) or are very persistent and very mobile (vPvM) in the aquatic environment, may pose a risk to surface water, ground water, and drinking water supplies. Despite the advances in liquid chromatography-mass spectrometry, there often exists an analytical blind spot when it comes to very polar chemicals. This study seeks to make a broad polarity range analytically accessible by means of serially coupling reversed-phase liquid chromato… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 38 publications
0
8
0
Order By: Relevance
“…With such HRMS/MS systems non-targeted screening (NTS) analysis of 'unknown' PMT/vPvM molecules can be conducted. There are several openly accessible platforms such as XCMS [43], MZmine [44], FOR-IDENT [45] and patRoon [46], which cover parts of or the entire NTS data evaluation and prioritization [48] adapted with polarity extended chromatography [49] process. Using polarity extended chromatography, HRMS, FOR-IDENT and compound databases, several vPvM substances (in the log D ow range from − 9 to + 9) such as N,N′-ethylenedi(diacetamide) [12] or 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-ethanol [47] could be identified in surface waters and other aqueous samples [12,40,[42][43][44].…”
Section: Getting In Control Of Analytical Methods and Monitoring Of P...mentioning
confidence: 99%
“…With such HRMS/MS systems non-targeted screening (NTS) analysis of 'unknown' PMT/vPvM molecules can be conducted. There are several openly accessible platforms such as XCMS [43], MZmine [44], FOR-IDENT [45] and patRoon [46], which cover parts of or the entire NTS data evaluation and prioritization [48] adapted with polarity extended chromatography [49] process. Using polarity extended chromatography, HRMS, FOR-IDENT and compound databases, several vPvM substances (in the log D ow range from − 9 to + 9) such as N,N′-ethylenedi(diacetamide) [12] or 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-ethanol [47] could be identified in surface waters and other aqueous samples [12,40,[42][43][44].…”
Section: Getting In Control Of Analytical Methods and Monitoring Of P...mentioning
confidence: 99%
“…In RPLC and HILIC there is a good correlation of retention time and hydrophobicity (or polarity). In the serial LC coupling, the retention time of molecules can be used to estimate the polarity of unknown compounds and thus to support their identification 10 . Unfortunately, there is currently no such estimation available based on retention time in SFC so far.…”
Section: Challenges and Opportunities In Sfc Methods Developmentmentioning
confidence: 99%
“…Chromatographic parameters such as RT can be connected to the physicochemical properties of an analyte. Our group demonstrated the benefits of this relationship by filtering for polar compound candidates 51,52 . NTS measurements were carried out on a chromatographic setup comprising reversed‐phase LC (RPLC) coupled in series to hydrophilic interaction liquid chromatography (HILIC) for the separation of analytes of an extended polarity range 53 .…”
Section: Prioritizationmentioning
confidence: 99%
“…Our group demonstrated the benefits of this relationship by filtering for polar compound candidates. 51,52 NTS measurements were carried out on a chromatographic setup comprising reversed-phase LC (RPLC) coupled in series to hydrophilic interaction liquid chromatography (HILIC)…”
Section: Prioritizationmentioning
confidence: 99%