2018 IEEE Applied Power Electronics Conference and Exposition (APEC) 2018
DOI: 10.1109/apec.2018.8341299
|View full text |Cite
|
Sign up to set email alerts
|

Optimized hybrid PWM scheme for mitigating zero-crossing distortion in totem-pole bridgeless PFC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…However, the total harmonic distortion (THD) of output current is 4.2% when the output power is 600 W, and it complies with the standard IEEE 519. In [24], an optimised hybrid PWM scheme is proposed to mitigate the zero-crossing distortion to improve THD. The experimental results demonstrate that the proposed current sharing control can equalise the output currents of two high-frequency arms and maintain a sinusoidal output current from the interleaved AC-DC power converter even under the transient of power change.…”
Section: Resultsmentioning
confidence: 99%
“…However, the total harmonic distortion (THD) of output current is 4.2% when the output power is 600 W, and it complies with the standard IEEE 519. In [24], an optimised hybrid PWM scheme is proposed to mitigate the zero-crossing distortion to improve THD. The experimental results demonstrate that the proposed current sharing control can equalise the output currents of two high-frequency arms and maintain a sinusoidal output current from the interleaved AC-DC power converter even under the transient of power change.…”
Section: Resultsmentioning
confidence: 99%
“…Note that the maximum values tend to infinite when wt = 0 and wt = π, while the minimum value is presented with wt = π/2. Fulfilment of the transversality condition in the complete range of operation is given when the α 1 /α 2 ratio is less than the minimum value of the curve (see (14)). According to Figure 2,(14) better expresses the condition of (13).…”
Section: Third Step: Validation Of Transversality Conditionmentioning
confidence: 99%
“…SBBC controllers are usually based on classic cascade PI or linear controllers which feature an external voltage loop and an inner current loop that use Pulse Width Modulation (PWM) for generating the required control signals and activating power switches. However, this kind of controllers present start-up overvoltages causing instability and affecting sensitive loads [10,[13][14][15][16][17]. Particularly, Kim et al [17] made a comparative analysis for PFC of several high efficiency AC/DC boost topologies.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the field of speech signal processing, short-term average zero-crossing rates are commonly used for endpoint detection of unvoiced and voiced speech. e zero-crossing rate is the ratio of the sign change of a signal [23]. If it is a sinusoidal signal, its average zerocrossing rate is twice the signal frequency divided by the sampling frequency, and the sampling frequency is fixed.…”
Section: Short-term Interval Zero-crossing Ratementioning
confidence: 99%