2010
DOI: 10.1051/epjconf/20100622019
|View full text |Cite
|
Sign up to set email alerts
|

Optimized optical setup for DIC in rock mechanics

Abstract: Abstract. In order to investigate the micromechanical mechanisms of argillaceous rocks under combined mechanical load and varying moisture, and observe very low strain rates of about 10 -10 s -1 , i.e. about 10 -4 per week, a specific optical setup for DigitalImage Correlation (DIC) has been developed at the Solids Mechanics Laboratory, Ecole Polytechnique. This paper mainly presents two procedures to optimize the experimental setup and enhance the full-field strain measurement accuracy. The first one allows u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(19 citation statements)
references
References 6 publications
1
18
0
Order By: Relevance
“…Beam size and scanning rate are also adjusted to get a good compromise between the quality of the signal to noise ratio and the problem of electrical charge accumulation. Noise levels are however larger in SEM images than in optical images, as discussed by Yang et al (2010).…”
Section: Uniaxial Compression Tests Coupled To Sem Imagingmentioning
confidence: 95%
See 2 more Smart Citations
“…Beam size and scanning rate are also adjusted to get a good compromise between the quality of the signal to noise ratio and the problem of electrical charge accumulation. Noise levels are however larger in SEM images than in optical images, as discussed by Yang et al (2010).…”
Section: Uniaxial Compression Tests Coupled To Sem Imagingmentioning
confidence: 95%
“…The quantification of the errors due to an overall uniform out-of-plane motion is further discussed in Section 5. Additional general discussions on these aspects can be found in Sutton et al (2008) and an ad-hoc improvement of the present set-up is described by Yang et al (2010).…”
Section: Strain Field Computationmentioning
confidence: 99%
See 1 more Smart Citation
“…In an attempt to evaluate systematic errors associated with subpixel displacements (so-called 'S curve') the method proposed by [38] was used. Successive images of the fixed specimen were taken for small camera translations along the optical axis.…”
Section: Dic Resolutionmentioning
confidence: 99%
“…The identification procedure of the prior stochastic model of this apparent elasticity field is detailed in Nguyen (2013); Nguyen et al (2015) for which the measurements of the displacement field are required both at the macroscopic scale and at the mesoscopic scale. The implementation of the experimental methodology by optical measurements of mechanical fields, the development of a measuring bench, the specimen preparation, the experimental measurements, and the DIC method, have already been the object of research in the context of biological materials Bertolino et al (2007); Bornert et al (2010); Chauvet et al (2010); Gusachenko et al (2012); Heripre et al (2007); Houssen et al (2011); Kalouche et al (2010); Yang et al (2012Yang et al ( , 2010; Yamaguchi et al (2011). In this paper, new advances are proposed to circumvent the difficulties induced by the complex nature of the cortical bone and the need to observe for the same loading two very different scales.…”
Section: Introductionmentioning