1984
DOI: 10.1088/0031-9155/29/3/004
|View full text |Cite
|
Sign up to set email alerts
|

Optimum x-ray spectra for mammography: choice of K-edge filters for tungsten anode tubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

1986
1986
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 2 publications
0
10
0
1
Order By: Relevance
“…The calculated optimum mean x-ray energies are in the range of 15-18 keV and 21.5-25 keV for a 2.5 and 8 cm thick breast, respectively. [17][18][19][20][21][22] It can be shown that if polychromatic radiation with a fixed photon energy distribution is used, such as that produced by a standard Mo x-ray tube, the photon fluence that is in the optimum band for a given breast thickness decreases dramatically for thicker breasts; e.g., for the Mo/0.03 mm Mo system, it decreases from 57% to 6% for 2.5 and 8 cm breast thicknesses, respectively.…”
Section: B the X-ray Beam Qualitymentioning
confidence: 99%
“…The calculated optimum mean x-ray energies are in the range of 15-18 keV and 21.5-25 keV for a 2.5 and 8 cm thick breast, respectively. [17][18][19][20][21][22] It can be shown that if polychromatic radiation with a fixed photon energy distribution is used, such as that produced by a standard Mo x-ray tube, the photon fluence that is in the optimum band for a given breast thickness decreases dramatically for thicker breasts; e.g., for the Mo/0.03 mm Mo system, it decreases from 57% to 6% for 2.5 and 8 cm breast thicknesses, respectively.…”
Section: B the X-ray Beam Qualitymentioning
confidence: 99%
“…Recently, it has been suggested that x-ray tubes with tungsten anodes used with palladium filters would give images comparable to molybdenum tubes (7,8,30). An example of a primary mammographic spectrum at 30 kYp with a tungsten anode is also shown in Fig.…”
Section: Basic Considerationsmentioning
confidence: 99%
“…Fig. 13 shows that the scatter to primary ratio increases with increasing tube potential within the potential interval investigated (22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36) when no grid is employed. Using a grid, the scatter to primary ratio is more or less constant with tube potential.…”
Section: Basic Considerationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Por outro lado, o espectro de raios X emitido por um tubo com anodo de tungstênio, na região de energia utilizada em mamografia,é formado principalmente por radiação contínua (Bremsstrahlung) (Figura 2.2). Para que o espectro produzido por um tubo de raios X com anodo de tungstênio possa ser utilizado em mamografiaé necessário utilizar filtros com bordas de absorção (K-edge) em energias apropriadas a fim de subtrair do espectro a parcela de fótons acima de uma dada energia que degrada a imagem e a parcela da radiação de baixa energia que aumenta a dose de radiação recebida pela paciente e que não contribui para a formação da imagem [47][48][49][50][51][52].…”
Section: Caracterização Dos Sistemas De Raios X 221 Adaptação Do Siunclassified