Space Telescopes and Instrumentation 2018: Optical, Infrared, and Millimeter Wave 2018
DOI: 10.1117/12.2314487
|View full text |Cite
|
Sign up to set email alerts
|

Optomechanical modeling of the optical telescope element and integrated science instrument module (OTIS) cryo-vacuum test for the James Webb Space Telescope (JWST)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…3 that the evaluation accuracy of the LCT’s LOS stability is up to the optical sensitivity matrix and the RBD calculation of the optical surface. Hence, the correctness of the LCT’s integrated modeling and analysis could be demonstrated by verifying the calculation method of the optical surfaces’ RBD since the feasibility of the linear optical sensitivity matrix obtained from the image point caused by the perturbation has been well proved in past studies 20 , 29 , 31 , 32 …”
Section: Experimental Verificationmentioning
confidence: 91%
See 1 more Smart Citation
“…3 that the evaluation accuracy of the LCT’s LOS stability is up to the optical sensitivity matrix and the RBD calculation of the optical surface. Hence, the correctness of the LCT’s integrated modeling and analysis could be demonstrated by verifying the calculation method of the optical surfaces’ RBD since the feasibility of the linear optical sensitivity matrix obtained from the image point caused by the perturbation has been well proved in past studies 20 , 29 , 31 , 32 …”
Section: Experimental Verificationmentioning
confidence: 91%
“…Hence, the correctness of the LCT's integrated modeling and analysis could be demonstrated by verifying the calculation method of the optical surfaces' RBD since the feasibility of the linear optical sensitivity matrix obtained from the image point caused by the perturbation has been well proved in past studies. 20,29,31,32 The simulation and verification experiment of the RBDs calculated by the dual quaternion is illustrated in Fig. 15.…”
Section: Optical Sensitivity Of the Truss Rod Section Thicknessmentioning
confidence: 99%
“…The cryogenic lens in the device uses a flexible bonding scheme. The Near Infrared Camera (NIRCam) instrument for NASA's JWSTJ (ames Webb Space Telescope) was launched in 2021 42 . The lens support system in this instrument is a flexure ring that belongs to anywhere from eight to sixteen flexure springs that hold the lens axially, and an additional eight to sixteen springs that hold the lens radially.…”
Section: Development Of Low Temperature Flexible Supportmentioning
confidence: 99%