2022
DOI: 10.1007/s13402-022-00750-0
|View full text |Cite
|
Sign up to set email alerts
|

OrBITS: label-free and time-lapse monitoring of patient derived organoids for advanced drug screening

Abstract: Background Patient-derived organoids are invaluable for fundamental and translational cancer research and holds great promise for personalized medicine. However, the shortage of available analysis methods, which are often single-time point, severely impede the potential and routine use of organoids for basic research, clinical practise, and pharmaceutical and industrial applications. Methods Here, we developed a high-throughput compatible and automated liv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(25 citation statements)
references
References 25 publications
0
25
0
Order By: Relevance
“…As expected, a variation in the number and mean area of PDTOs was observed between the wells (Figure 2A,B). The total survival area (total brightfield area -total green area) combines the labelfree organoid segmentation with the fluorescence-based cell death signal and is, in our experience, the most robust parameter to study drug responses over time (Figure 2C) 8 .…”
Section: Representative Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…As expected, a variation in the number and mean area of PDTOs was observed between the wells (Figure 2A,B). The total survival area (total brightfield area -total green area) combines the labelfree organoid segmentation with the fluorescence-based cell death signal and is, in our experience, the most robust parameter to study drug responses over time (Figure 2C) 8 .…”
Section: Representative Resultsmentioning
confidence: 99%
“…In addition, the analysis is compatible with other live-cell imaging systems, as previously shown for phase-contrast images captured with an IncuCyte ZOOM system 8 . A limitation of the Spark Cyto live-cell imaging system that was used in this manuscript is the one-plate capacity for kinetic measurements.…”
Section: Cell Suspension Stockmentioning
confidence: 91%
See 2 more Smart Citations
“…Three-day-old spheroids were harvested using Cultrex organoid harvesting solution and counted in a black 384-well plate using the Spark Cyto and in-house developed image analysis software Orbits [ 38 ]. Next, the spheroid seeding solution, consisting of the harvested 344SQ spheroids and 4% Cultrex Type 2, was automatically seeded under cold conditions in a precooled black 384-well plate at a concentration of 200 spheroids per well using the OT-2 pipetting robot.…”
Section: Methodsmentioning
confidence: 99%