1996
DOI: 10.1002/(sici)1521-186x(1996)17:4<335::aid-bem10>3.0.co;2-n
|View full text |Cite
|
Sign up to set email alerts
|

Orientation of glutaraldehyde-fixed erythrocytes in strong static magnetic fields

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
47
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 49 publications
(48 citation statements)
references
References 11 publications
1
47
0
Order By: Relevance
“…The magnetic orientation of biological cells and molecules in static magnetic ®elds has been reported for purple membranes from halophiles (Halobacterium alobium) [Neugebauer et al, 1977], erythrocytes [Murayama M, 1965;Higashi et al, 1993aHigashi et al, , 1995Suda et al, 1994], platelets [Yamagishi et al, 1992;Higashi et al, 1993b], and ®brin ®bers [Yamagishi et al, 1990;Iwasaka et al, 1994]. Purple membranes of halophiles are oriented perpendicular to the magnetic ®eld [Neugebauer et al, 1977].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The magnetic orientation of biological cells and molecules in static magnetic ®elds has been reported for purple membranes from halophiles (Halobacterium alobium) [Neugebauer et al, 1977], erythrocytes [Murayama M, 1965;Higashi et al, 1993aHigashi et al, , 1995Suda et al, 1994], platelets [Yamagishi et al, 1992;Higashi et al, 1993b], and ®brin ®bers [Yamagishi et al, 1990;Iwasaka et al, 1994]. Purple membranes of halophiles are oriented perpendicular to the magnetic ®eld [Neugebauer et al, 1977].…”
Section: Introductionmentioning
confidence: 99%
“…Purple membranes of halophiles are oriented perpendicular to the magnetic ®eld [Neugebauer et al, 1977]. In contrast, intact erythrocytes are oriented with their disk plane parallel to it [Higashi et al, 1993a]. These orientations can be explained mainly by the diamagnetic anisotropy of two cell membrane components, the lipid bilayer and the transmembrane proteins.…”
Section: Introductionmentioning
confidence: 99%
“…The hematocrit value of erythrocyte suspensions with several osmolalities was adjusted to the same value. The samples were equilibrated in air for at least 1 h before ESR measurement to obtain diamagnetic oxyhemoglobin [Higashi et al, 1993]. The cells were used within 6 h after collection of blood.…”
Section: Methodsmentioning
confidence: 99%
“…The remaining determinant which cannot cause the magnetic enhancement for isotropic spheres, is a magnetic ®eld±induced increase in an intracellular adhesive membrane area due to the magnetic orientation of an anisotropic erythrocyte [Suda and Ueno, 1994;Higashi et al, 1995Higashi et al, , 1996Suda and Ueno, 1996]. It is noted that the possibility of the existence of the above-mentioned determinants is not completely eliminated.…”
Section: Mass Conservation Of Intracellular Hemoglobin the Equation mentioning
confidence: 99%
See 1 more Smart Citation