Orthogonal array design for the optimization of closed-vessel microwave digestion parameters for the determination of trace metals in sediments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
14
1
2

Year Published

1996
1996
2022
2022

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(17 citation statements)
references
References 16 publications
0
14
1
2
Order By: Relevance
“…Our observations regarding digestion time differ somewhat from those of Zhou, et al (1995), who suggested that changes in microwave digestion time should not affect recoveries. The authors do not imply that the digestion time has no effect on the sample decomposition; they simply indicate that 15 min is sufficient to complete the digestion of most samples and that varying the digestion times should not have statistical significance.…”
Section: Table VIcontrasting
confidence: 98%
“…Our observations regarding digestion time differ somewhat from those of Zhou, et al (1995), who suggested that changes in microwave digestion time should not affect recoveries. The authors do not imply that the digestion time has no effect on the sample decomposition; they simply indicate that 15 min is sufficient to complete the digestion of most samples and that varying the digestion times should not have statistical significance.…”
Section: Table VIcontrasting
confidence: 98%
“…Since most sediment samples contain relatively small amount of organic substances, the quick-digestion program is suitable for their digestion. 12 The maximum microwave output can reduce the digestion time, and a high-pressure setting can increase the temperature in the digestion vessel. Thirty minutes would be sufficient for the complete digestion of a soil matrix.l°,12 Hence, quick digestion with 100% power output, a pressure setting at 1035 kPa (150 psi), a temperature setting at 200°C and a time of 30 min were used in this study.…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…FIA-CV-AAS has become the most widely used method for mercury determination. 12,5,6 Different complex matrices of the analytical sample require prior mineralization for most analytical methods. The two types of digestion methods which are commonly employed for determining trace metals are wet digestion and dry ashing.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…All the representative combinations distribute uniformly in the research area and can greatly reflect the situation of the whole selected examined area. This method has proven to be a cost-effective optimization strategy that can obtain the optimal conditions of each parameter in a limited number of experimental trials [24][25][26][27]. Therefore, this paper discussed four main process conditions in the transesterification reaction (i.e.…”
Section: Introductionmentioning
confidence: 99%