2019
DOI: 10.1364/osac.2.003514
|View full text |Cite
|
Sign up to set email alerts
|

Orthographic imaging of free-flowing aerosol particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…In order to improve the accuracy of particle localization along the depth direction, DIH has been integrated with tomographic methods to perform particle field measurements [8,[22][23][24][25][26][27][28][29][30][31]. Generally, in tomographic holography, several illumination beams (usually originating from a single laser source) pass through the object of interest along different directions to generate different projections for tomography.…”
Section: Hybrid Dh Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…In order to improve the accuracy of particle localization along the depth direction, DIH has been integrated with tomographic methods to perform particle field measurements [8,[22][23][24][25][26][27][28][29][30][31]. Generally, in tomographic holography, several illumination beams (usually originating from a single laser source) pass through the object of interest along different directions to generate different projections for tomography.…”
Section: Hybrid Dh Systemsmentioning
confidence: 99%
“…Considering the reflection of the mirrors, the deconvoluted light path is shown in the bottom of figure 3(a). On the other hand, if more sensors are used, each projection can be recorded by a single sensor [8,[23][24][25][26][27][28][29][30][31], as shown in figure 3(b), where three sensors are utilized to capture three holograms, respectively. Due to its flexibility, the latter strategy is frequently adopted to perform tomographic holography.…”
Section: Hybrid Dh Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…A critical advantage of Nano-DIHM is that, during reconstruction, a single 2D hologram can produce a 3D image of the objects without any loss of resolution 50 , 58 . The Octopus/Stingray software allows real-time or offline reconstruction with a temporal resolution on the order of milliseconds (62.5 ms) and it can be improved to microsecond-scale temporal resolution, depending on the frame rate of the camera 57 , 65 , 70 , 71 .…”
Section: Introductionmentioning
confidence: 99%
“…Using the IPI technique, we do not record the exact shape of the particles, but we obtain information about their dimensions, their orientations and morphology [22]. The characterization of irregular particles has become the object of intense efforts [23][24][25][26]. For an irregular rough particle such as an ice crystal, the interferometric out-of-focus image is a speckle-like pattern.…”
Section: Introductionmentioning
confidence: 99%