Out-of-field dose calculation by a commercial treatment planning system and comparison by monte carlo simulation for varian TrueBeam®

Abstract: Purpose:The calculation accuracy of treatment planning systems (TPSs) drops drastically when the points outside the field edges are considered. The real accuracy of a TPS and linear accelerator (linac) combination for regions outside the field edge is a subject which demands more study. In this study, the accuracy of out-of-field dose calculated by a TPS, used with a TrueBeam® (TB) linac, is quantified.Materials and Methods:For dose calculation, Eclipse™ version 13.7 commissioned for TB machine was used. For c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
6
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 25 publications
2
6
0
2
Order By: Relevance
“…First, treatment planning systems are known to underestimate the collimator scatter and scatter from other components of the beam line, which directly affect the out-of-field dose calculations. Therefore, for organs further away from the target, the dose discrepancies increased, in accordance with the previous studies [14,15]. Second, in the treatment planning process, manual contouring was done to delineate the organs and structures of interest.…”
Section: Deterministic Effects and Stochastic Effects Of The Fetussupporting
confidence: 72%
“…First, treatment planning systems are known to underestimate the collimator scatter and scatter from other components of the beam line, which directly affect the out-of-field dose calculations. Therefore, for organs further away from the target, the dose discrepancies increased, in accordance with the previous studies [14,15]. Second, in the treatment planning process, manual contouring was done to delineate the organs and structures of interest.…”
Section: Deterministic Effects and Stochastic Effects Of The Fetussupporting
confidence: 72%
“…We utilized a previously developed clinically available automatic VMAT QA system for this study [ 37 ]. The system is designed to re-calculate the beam sequence of equipment and treatment plan using the Monte Carlo engine, so it is possible to accurately calculate and evaluate scatter and leakage radiation, difficult to calculate in TPS [ 38 ]. The basic program was designed for QA, so the module was additionally configured to enable dose calculation using patient CT data.…”
Section: Methodsmentioning
confidence: 99%
“…A tabela 1 apresenta as doses em órgãos de interesse, dentro e fora do campo de tratamento, obtidas experimentalmente a partir de medições em TLDs posicionados em um fantoma irradiado em simulações do tratamento radioterápico do linfoma de Hodgkin, e as respectivas distâncias dos TLD à borda do campo. inferiores em relação às doses medidas com TLDs [21][22][23][24]. O cálculo da dose feito pelo sistema de planejamento utilizado é baseado em modelos de convolução separados para fótons primários e fótons extra focais dispersos (fótons não originados no ponto focal do alvo).…”
Section: Figura 1: Distribuição De Doses Construída Pelo Sistema De Planejamento (Visão Transversal)unclassified
“…Essa pequena diferença percentual pode ser explicada pelo fato de o cérebro estar no eixo central de irradiação, numa posição mais próxima da borda do campo do que os demais órgãos avaliados. Na literatura tem sido reportada a necessidade de correções para as regiões fora do campo[21][22][23]. Howell et al, Huang…”
unclassified