2017
DOI: 10.1049/iet-opt.2016.0057
|View full text |Cite
|
Sign up to set email alerts
|

Outage probability of WDM free‐space optical systems affected by turbulence‐accentuated interchannel crosstalk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
30
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(30 citation statements)
references
References 28 publications
0
30
0
Order By: Relevance
“…The DPPM thermal noise variance is back calculated using a bandwidth expansion factor such that σ th−DPPM = 7 10 −7 A is obtained from a model of a positive-intrinsic-negative (PIN)field effect transistor receiver with R b = 2.5 Gbps at BER of 10 −12 assuming a sensitivity of 23 dBm [7,38,[42][43][44][45][46][47][48]. The demux (or OBPF) channel bandwidth is 80 GHz with 100 GHz adjacent channel spacing, this is about the same with those seen in [39,40] and will easily accommodate the slot rate of 45.7 GHz for maximum DPPM coding level of M = 7 considered [7,17,[46][47][48][49][50]. Typical values for adjacent channel rejection ratio ranges from 20 dB to 30 dB [7,[39][40][41][50][51][52][53][54].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The DPPM thermal noise variance is back calculated using a bandwidth expansion factor such that σ th−DPPM = 7 10 −7 A is obtained from a model of a positive-intrinsic-negative (PIN)field effect transistor receiver with R b = 2.5 Gbps at BER of 10 −12 assuming a sensitivity of 23 dBm [7,38,[42][43][44][45][46][47][48]. The demux (or OBPF) channel bandwidth is 80 GHz with 100 GHz adjacent channel spacing, this is about the same with those seen in [39,40] and will easily accommodate the slot rate of 45.7 GHz for maximum DPPM coding level of M = 7 considered [7,17,[46][47][48][49][50]. Typical values for adjacent channel rejection ratio ranges from 20 dB to 30 dB [7,[39][40][41][50][51][52][53][54].…”
Section: Resultsmentioning
confidence: 99%
“…Typical values for adjacent channel rejection ratio ranges from 20 dB to 30 dB [7,[39][40][41][50][51][52][53][54]. It can be deduced from the plots that the DPPM technique is capable of providing better performance when compared to the OOK-NRZ technique [7,[36][37][38][39][40][48][49][50][51][52][53][54]. Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The scintillation index of fading is 1. The channel fading AMPLITIDE "a" for Rayleigh distribution or PDF gain is written in [15,[40][41][42][43][44][45] (a)=2ae −a 2 (45)…”
Section: A Rayleigh Distributionmentioning
confidence: 99%
“…The Lognormal model is used in cases less fading (weak turbulence) [38][39][40][41][42][43][44][45].…”
Section: B Log-normal Distributionmentioning
confidence: 99%