2013
DOI: 10.1016/j.jhin.2013.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Outbreak of ertapenem-resistant Enterobacter cloacae urinary tract infections due to a contaminated ureteroscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
56
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 82 publications
(56 citation statements)
references
References 19 publications
0
56
0
Order By: Relevance
“…11 In light of growing concerns over severe infections transmitted with reusable duodenoscopes, 15 utilizing a single-use ureteroscope may help allay fears of both patients and providers that a reusable ureteroscope might one day be discovered to be a source of an infection. 16 Single-use products may be easier for facilities, reducing the system stressors placed on the hospital and central processing by the needs of scope reprocessing and maintenance. In line with these potential advantages, understanding the clinical performance of LithoVue bears exploration.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…11 In light of growing concerns over severe infections transmitted with reusable duodenoscopes, 15 utilizing a single-use ureteroscope may help allay fears of both patients and providers that a reusable ureteroscope might one day be discovered to be a source of an infection. 16 Single-use products may be easier for facilities, reducing the system stressors placed on the hospital and central processing by the needs of scope reprocessing and maintenance. In line with these potential advantages, understanding the clinical performance of LithoVue bears exploration.…”
Section: Discussionmentioning
confidence: 99%
“…With regard to the difference in complication rates, the fact that the complications occurring in the control reusable scope group were not related to infection indicates that these differences were possibly reflective of the study design rather than a factor intrinsically related to the ureteroscopes themselves. If there were differences in infection rates between the two groups, one might consider the reprocessing of reusable scopes as a reason to account for these differences 16 ; however, this was not the case.…”
Section: Discussionmentioning
confidence: 99%
“…Other types of flexible endoscopic procedures, including bronchoscopy and cystoscopy (as well as other types of medical procedures unrelated to flexible endoscopy), are also identified risk factors for infections (and predictors for colonizations) with CRE and related superbugs [23,44,45] . Indeed, some infection-control measures designed to prevent CRE transmission during GI endoscopy may also be employed during these other flexible endoscopic procedures for the successful prevention of infection.…”
Section: Transmission Of Cre and Related Superbugs During Other Typesmentioning
confidence: 99%
“…For example, Koo et al [23] (2012) discuss an outbreak of NDM-1 K. pneumoniae linked to contamination of the video camera head of urological instrumentation. Chang et al [44] (2013) similarly report a CRE outbreak at a regional teaching hospital in southern Taiwan, finding an ureteroscope contaminated with ertapen-…”
Section: Transmission Of Cre and Related Superbugs During Other Typesmentioning
confidence: 99%
See 1 more Smart Citation