2022
DOI: 10.1177/17585732221088290
|View full text |Cite
|
Sign up to set email alerts
|

Outcomes of elbow fracture-dislocations treated with and without an Internal Joint Stabilizer of the Elbow (IJS-E): A retrospective cohort study

Abstract: Background The internal joint stabilizer of the elbow (IJS-E) adds to techniques for maintaining reduction of elbow fracture-dislocations while allowing early motion. Literature on this device is limited to small case series. Methods Retrospective comparison of function, motion and complications in patients who sustained elbow fracture-dislocations reconstructed with (30 patients) and without (34 patients) an IJS-E by a single surgeon. The minimum follow up was 10 weeks. Results The mean follow up was 16 ± 17 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…A total of nine retrospective reports on the IJS with a sample of 171 cases and a mean follow-up of 10.8 months were included ( Table 1 ). 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 The mean MCMS was 61 (range: 56–67), which indicates a moderate quality of reporting across all groups. Indications are detailed in Table 2 , and device-related complications are demonstrated in Table 3 .…”
Section: Resultsmentioning
confidence: 97%
See 3 more Smart Citations
“…A total of nine retrospective reports on the IJS with a sample of 171 cases and a mean follow-up of 10.8 months were included ( Table 1 ). 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 The mean MCMS was 61 (range: 56–67), which indicates a moderate quality of reporting across all groups. Indications are detailed in Table 2 , and device-related complications are demonstrated in Table 3 .…”
Section: Resultsmentioning
confidence: 97%
“…The most common injury pattern for which the IJS was indicated was acute presentation of a terrible triad (53%). Across seven articles, the mean Disabilities of the Arm, Shoulder, and Hand score was 22.4 (range: 11.7–37), 10 , 11 , 12 , 13 , 14 , 15 , 17 and across four articles, the mean Mayo Elbow Performance Score (MEPS) was 82 (range: 74–94). 13 , 14 , 15 , 17 All nine articles reported the elbow flexion extension arc for a mean of 111°.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…5 ). 29 , 32 The proximal radius was prepared for arthroplasty according to the previously described technique (Align; Skeletal Dynamics, Miami, FL, USA). 11 , 21 Prosthetic length was determined in relation to the corner formed by the lesser and greater sigmoid notch when evaluated on a true anteroposterior fluoroscopic image with the forearm in supination.…”
Section: Case Reportmentioning
confidence: 99%