2012
DOI: 10.1097/ijg.0b013e318227a565
|View full text |Cite
|
Sign up to set email alerts
|

Outcomes of Fornix-based Versus Limbus-based Conjunctival Incisions for Glaucoma Drainage Device Implant

Abstract: Both incision techniques were equally effective in controlling IOP. Each surgical approach has its advantages and this study suggests that either technique may be used safely and effectively.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0
2

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 27 publications
0
7
0
2
Order By: Relevance
“…Moreover, there was a tendency for the increased occurrence of a shallow anterior chamber in the LBCF group (OR = 1.38, 95% CI: 0.97 to 1.98; P = 0.076). This may be due to the increased exposition of sclera and subconjunctival tissue with this technique: the initial outflow resistance in the subconjunctival space may be lower, as the initial hypotony was more pronounced when the subconjunctival tissue was opened over a larger area[37], [38]. However, no significant between-group differences in complications were found in the current meta-analysis.…”
Section: Discussionmentioning
confidence: 62%
“…Moreover, there was a tendency for the increased occurrence of a shallow anterior chamber in the LBCF group (OR = 1.38, 95% CI: 0.97 to 1.98; P = 0.076). This may be due to the increased exposition of sclera and subconjunctival tissue with this technique: the initial outflow resistance in the subconjunctival space may be lower, as the initial hypotony was more pronounced when the subconjunctival tissue was opened over a larger area[37], [38]. However, no significant between-group differences in complications were found in the current meta-analysis.…”
Section: Discussionmentioning
confidence: 62%
“…The Argus II design incorporates transcleral cables, which may increase risk of infection 22 23. Image processing is as follows: data from the external camera are transferred to a processor and transmitter coil, then wirelessly to an electronics case.…”
Section: Resultsmentioning
confidence: 99%
“…Intraocular designs, which minimally disrupt barriers between patients’ internal body cavity and the outside environment, should reduce the risk of infection with chronic ocular implants 22 23. Alpha-IMS uses intraocular light-sensitive photodiodes for image acquisition, allowing microsaccades to help prevent image fading and better simulate natural vision.…”
Section: Discussionmentioning
confidence: 99%
“…37 Suhr ve ark. 38 160 gözde implantın yerleştirilmesi için açılan konjonktival insizyonun limbus (69 göz) veya forniks (91 göz) tabanlı olmasına göre iki gruba ayırarak yaptıkları çalışmada her iki gruba da aynı antibiyotik proflaksisi uygulanmasına rağmen, şant cerrahisinden sonraki bir yıl içerisinde limbus tabanlı konjonktival insizyonlarda hiç endoftalmi görülmezken, forniks tabanlı insizyonlarda üç gözde endoftalmi geliştiği bildirmişlerdir. Forniks tabanlı insizyonlarda, sklerostomi sahasından mikroorganizmaların glob içine erişiminin daha kolay olması nedeniyle endoftalmi oranının fazla olabileceğini öne sürmüşlerdir.…”
Section: öNlemeunclassified
“…Forniks tabanlı insizyonlarda, sklerostomi sahasından mikroorganizmaların glob içine erişiminin daha kolay olması nedeniyle endoftalmi oranının fazla olabileceğini öne sürmüşlerdir. 38 GDİ cerrahisi sonrası steril endoftalmi de bildirilmiştir ve bu durum enfeksiyonu taklit edebilir. 39 Steril endoftalmi, tek başına steroid tedavisine iyi yanıt verdiği için enfeksiyöz ve non-enfeksiyöz endoftalmi ayırımını yapmak çok önemlidir.…”