Overcoming the power factor apparent degradation of loads fed by photovoltaic distributed generators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
3
0
2

Year Published

2021
2021
2025
2025

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 17 publications
0
3
0
2
Order By: Relevance
“…A smart meter at each PCC registers the instantaneous active and reactive power flows, integrating them over a measuring interval t [19]. The MV prosumer's apparent power demand at time interval t is denoted as S d,t , where P d,t and Q d,t are the prosumer's active and reactive power demand at time interval t, respectively.…”
Section: A the Equipment Installed In Each Prosumermentioning
confidence: 99%
See 1 more Smart Citation
“…A smart meter at each PCC registers the instantaneous active and reactive power flows, integrating them over a measuring interval t [19]. The MV prosumer's apparent power demand at time interval t is denoted as S d,t , where P d,t and Q d,t are the prosumer's active and reactive power demand at time interval t, respectively.…”
Section: A the Equipment Installed In Each Prosumermentioning
confidence: 99%
“…It is important to note that if the magnitude of P P V,t increases, the value of the power factor measured at the PCC, f c t , is degraded [19]. This degradation occurs even though the demand load curve of the MV prosumer does not change.…”
Section: A the Equipment Installed In Each Prosumermentioning
confidence: 99%
“…The decrease in implementation costs, the development of new inverter technologies, low environmental impact rates, and growing incentive policies are responsible for this trend. Generally, PVG operates with a unity power factor, i.e., there is no generation or absorption of reactive power by the Photovoltaic Inverter (PVI) at the Connection Point (CP) [8]. However, implementing reactive power control is an important measure for mitigating losses and managing grid voltage levels effectively in DNs [9].…”
Section: Introduction 1motivationmentioning
confidence: 99%
“…Uma segunda abordagem que não implica em custos diretos para os geradores distribuídos é o controle da componente reativa de corrente, de forma a reduzir a sobretensão causada pelo fluxo de reativos na rede, com operação de forma similar à inserção de banco de capacitores ou d-STATCOM (Figura 1.11). O estudo desenvolvido em [30] descreve em detalhes o uso de geradores distribuídos com base em inversores e o uso de banco de capacitores para controle de reativos em relação à rede elétrica de distribuição, porém com o foco em controle de reativos em tempo real, de forma a aumentar o fator de potência do ponto de vista dos medidores de energia das unidades consumidoras. Este aumento de fator de potência está diretamente ligado à interação entre os vetores de rede exemplificados na Figura 1.12 e na Figura 1.13 e, portanto, acarreta uma diminuição da sobretensão causada pela injeção de corrente no ponto de conexão dos geradores distribuídos.…”
Section: Impactos Da Alta Penetração Da Geração Distribuída Na Rede E...unclassified
“…Ainda assim, sistemas baseados em inversores possuem uma curva de capacidade de operação conforme destacado em [30], caracterizada pela Figura 1.17.…”
Section: Impactos Da Alta Penetração Da Geração Distribuída Na Rede E...unclassified