Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04.
DOI: 10.1109/apec.2004.1295920
|View full text |Cite
|
Sign up to set email alerts
|

Overview of PI-based solutions for the control of the DC-buses of a single-phase H-bridge multilevel active rectifier

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0
4

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(33 citation statements)
references
References 5 publications
0
29
0
4
Order By: Relevance
“…And the sum of the continuous switching functions S 1 +S 2. can be obtained from the value of u con /(u dc1 +u dc2 ), here u dc1 and u dc2 are capacitor voltage of the two H-bridges in series respectively. The correctness of the above control method has been proven [15]. This control scheme can be described in Fig.…”
Section: A Mathematical Model and Control Scheme Of The Systemmentioning
confidence: 95%
See 1 more Smart Citation
“…And the sum of the continuous switching functions S 1 +S 2. can be obtained from the value of u con /(u dc1 +u dc2 ), here u dc1 and u dc2 are capacitor voltage of the two H-bridges in series respectively. The correctness of the above control method has been proven [15]. This control scheme can be described in Fig.…”
Section: A Mathematical Model and Control Scheme Of The Systemmentioning
confidence: 95%
“…6 shows dynamic characteristics of DC-link voltages using three different balance strategies. Fig 6 (a) and (b) show the balance strategy proposed by [15], which didn't think about the unbalance loads range, so there are more ripples of DC-link voltages when big unbalanced loads occur after 0.6s, and its output synthetic wave gets worse to inject more harmonics to the grid. The balances strategy proposed by [17] is shown as in Fig.6 (c) and (d) could be seen that the DC-link voltages of the two cells couldn't be rebalanced when big unbalanced loads occur after 0.6s, although the system can be stable and work under the unity power factor.…”
Section: B a Modified Modulation For Extending Unbalanced Loads Rangementioning
confidence: 99%
“…The voltage and current vectors are shown in Fig.12 The input power of the modules can be controlled by adjusting the magnitudes of their output voltages [7]. When the PET is working under APF mode, there is no active current flowing through the modules.…”
Section: Voltage Balancing Controlmentioning
confidence: 99%
“…In literature various PWM schemes are used for CHB rectifier operation [6], [7]. Some PI based control has also been proposed in literatures for proper dc bus regulation [8]. But these are based on instantaneous control and also control is complicated.…”
Section: Introductionmentioning
confidence: 99%