2022
DOI: 10.23919/cjee.2022.000039
|View full text |Cite
|
Sign up to set email alerts
|

Overview of Planar Magnetics for High-frequency Resonant Converters

Abstract: With the continuous development of power supplies toward miniaturization, light weights, and high levels of integration, research on high-frequency resonant conversion based on planar magnetics is becoming extensive. Combining the soft-switching characteristics of resonant converters with those of wide bandgap devices, the switching frequency can be increase to the MHz range, and the power density of the entire system can be improved considerably. However, higher switching frequencies impose new requirements f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 76 publications
0
6
0
Order By: Relevance
“…The measurement of winding loss in magnetic devices is generally categorized into the impedance analysis method and the power measurement method. The impedance analysis method does not consider the effect of actual operating conditions on winding loss and is suitable for measuring winding loss with sinusoidal excitation [ 21 ]. While the power measurement method considers the actual operating conditions of the magnetic device, its measurement accuracy depends on impedance angle measurement.…”
Section: Experimental Analysis and Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The measurement of winding loss in magnetic devices is generally categorized into the impedance analysis method and the power measurement method. The impedance analysis method does not consider the effect of actual operating conditions on winding loss and is suitable for measuring winding loss with sinusoidal excitation [ 21 ]. While the power measurement method considers the actual operating conditions of the magnetic device, its measurement accuracy depends on impedance angle measurement.…”
Section: Experimental Analysis and Discussionmentioning
confidence: 99%
“…All parameters are fixed except conductor diameter and the number of turns, and a set of n values is set to fit the analytical equation between n and doptMF. The analytical equations for the winding losses are obtained by substituting the fitted equations into (7) and (22), and then the partial derivatives of the total losses are combined with (21) to obtain the optimum loss rate and number of turns for optimum winding design.…”
Section: Number Of Turnsmentioning
confidence: 99%
See 1 more Smart Citation
“…The integrated magnetic structure can eliminate magnetic flux, which helps reduce core size and the core loss [78] . Research on high-frequency resonant conversion based on planar magnetics is becoming extensive [79] . In Ref.…”
Section: Multiple Integrated Structurementioning
confidence: 99%
“…The only two online monitoring methods (partial discharge method and shield cage potential method) have relatively high detection limits and are susceptible to various electromagnetic pulses within the power system, leading to misjudgments. [6][7][8] Therefore, there is a critical need for a reliable online monitoring system for vacuum circuit breakers. Furthermore, the measurement of vacuum levels represents a major obstacle to the widespread adoption of highvoltage vacuum switches in power transmission systems.…”
Section: Introductionmentioning
confidence: 99%