2004
DOI: 10.1016/j.jnucmat.2004.07.018
|View full text |Cite
|
Sign up to set email alerts
|

Oxygen measurements in stagnant lead–bismuth eutectic using electrochemical sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
18
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 37 publications
(18 citation statements)
references
References 15 publications
0
18
0
Order By: Relevance
“…The upper part of the YSZ tube was sealed using alumina cement. This sensor with the Mo/Bi-Bi 2 O 3 reference electrode was similar to the Mo/Bi-Bi 2 O 3 reference sensor manufactured in other institutes (Courouau et al, 2002b;Konys et al, 2004;Kondo et al, 2006). The following two methods were employed for calibration of oxygen sensors: (1) comparison between measured EMF values and theoretical ones using two kinds of gases with different oxygen concentrations for the reference electrode and the working electrode, and (2) comparison between measured EMF values and theoretical ones in LBE with the parameter of temperature under the condition close to oxygen saturation in LBE.…”
Section: Electromotive Force Measurement Using Oxygen Sensorsmentioning
confidence: 70%
See 4 more Smart Citations
“…The upper part of the YSZ tube was sealed using alumina cement. This sensor with the Mo/Bi-Bi 2 O 3 reference electrode was similar to the Mo/Bi-Bi 2 O 3 reference sensor manufactured in other institutes (Courouau et al, 2002b;Konys et al, 2004;Kondo et al, 2006). The following two methods were employed for calibration of oxygen sensors: (1) comparison between measured EMF values and theoretical ones using two kinds of gases with different oxygen concentrations for the reference electrode and the working electrode, and (2) comparison between measured EMF values and theoretical ones in LBE with the parameter of temperature under the condition close to oxygen saturation in LBE.…”
Section: Electromotive Force Measurement Using Oxygen Sensorsmentioning
confidence: 70%
“…This procedure in LBE is a convenient and reliable calibration method of oxygen sensors. The YSZ sensors with the Pt/air reference electrode also showed good durability and reliability for a long time in LBE loop facilities at 550C (Konys et al, 2004). In static corrosion tests, the YSZ sensors with the Pt/air reference electrode have been used for a long time in our laboratory as the reliable oxygen sensor in liquid LBE.…”
Section: Long-term Performance Of Pt/gas Reference Sensorsmentioning
confidence: 91%
See 3 more Smart Citations