Oxygen Supplementation in Noninvasive Home Mechanical Ventilation: The Crucial Roles of CO2Exhalation Systems and Leakages

Abstract: BACKGROUND: When supplemental oxygen is added to noninvasive ventilation using a non-ICU ventilator, it is usually introduced with a preset flow into the circuit near the ventilator; however, the impact of different CO 2 exhalation systems and leaks on the actual F IO 2 and gas exchange has not been elucidated. METHODS: In a randomized, open-label, 4-treatment (2-by-2), 4-period crossover design, 4 daytime measurements (60 min each) were performed in 20 subjects receiving home mechanical noninvasive ventilatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
19
0
3

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 23 publications
0
19
0
3
Order By: Relevance
“…When oxygen is bled into the circuit or interface, the actual level of inspired F IO 2 can vary under the influence of several factors, such as intentional and unintentional leak through the interface or circuit, inspiratory and expiratory pressure settings of NIV, the interface, oxygen flow, and the oxygen administration site. [77][78][79] Oxygen supply is frequently administered via an oxygen port already built into the frame of the interface. The site of oxygen delivery into the circuit is the most important factor in determining inspired F IO 2 .…”
Section: Oxygen Supply and Interfacementioning
confidence: 99%
See 2 more Smart Citations
“…When oxygen is bled into the circuit or interface, the actual level of inspired F IO 2 can vary under the influence of several factors, such as intentional and unintentional leak through the interface or circuit, inspiratory and expiratory pressure settings of NIV, the interface, oxygen flow, and the oxygen administration site. [77][78][79] Oxygen supply is frequently administered via an oxygen port already built into the frame of the interface. The site of oxygen delivery into the circuit is the most important factor in determining inspired F IO 2 .…”
Section: Oxygen Supply and Interfacementioning
confidence: 99%
“…77 Administering oxygen into interface results in exhaustion of oxygen out of the exhalation port. 79 Furthermore, oxygen may leak unintentionally between the interface and the face, resulting in low F IO 2 and, hence, low arterial P aO 2 and oxygen saturation. Consequently, when oxygen is administered directly into an interface with a leak port, patients may receive very low oxygen concentrations, which may result in low oxygen saturation in the blood.…”
Section: Oxygen Supply and Interfacementioning
confidence: 99%
See 1 more Smart Citation
“…135 Leaks may decrease the F IO 2 when supplemental oxygen is administered during NIV and may lead to significant pressure drops, poor inspiratory triggering, increases in duration of inspiratory pressurization, and even inversion of the inspiratory-expiratory ratio. [135][136][137] Pressure drops induced by unintentional leaks depend on the ventilators tested because leak compensation varies markedly from one ventilator to another (Fig. 2).…”
Section: Leaks and Patient-ventilator Asynchronymentioning
confidence: 99%
“…132 Leaks have a clinically relevant deleterious impact in NIV. [134][135][136] In volume-cycled NIV, they lead to insufficient compensation of hypoventilation, lower V T , and lower PEEP and affect the ability of the patient to trigger the ventilator (Fig. 1).…”
Section: Leaks and Patient-ventilator Asynchronymentioning
confidence: 99%