1988
DOI: 10.1007/978-1-4615-9510-6
|View full text |Cite
|
Sign up to set email alerts
|

Oxygen Transport to Tissue X

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…For each participant, we evaluated relative changes in oxy-Hb and deoxy-Hb signals from an arbitrary 0 baseline at the beginning of the measurement period in units of millimolar millimeter, 26 using the modified Beer-Lambert Law with a differential path-length factor of 6 (more details about the differential path-length factor could be found in Refs. [27][28][29][30][31]. For each participant, the rs-fNIRS data were collected for ∼11 min, and the participants were instructed to relax, keep their eyes closed, and remain awake.…”
Section: Data Acquisitionmentioning
confidence: 99%
“…For each participant, we evaluated relative changes in oxy-Hb and deoxy-Hb signals from an arbitrary 0 baseline at the beginning of the measurement period in units of millimolar millimeter, 26 using the modified Beer-Lambert Law with a differential path-length factor of 6 (more details about the differential path-length factor could be found in Refs. [27][28][29][30][31]. For each participant, the rs-fNIRS data were collected for ∼11 min, and the participants were instructed to relax, keep their eyes closed, and remain awake.…”
Section: Data Acquisitionmentioning
confidence: 99%
“…We utilized the multichannel fNIRS system ETG-4000 (Hitachi Medical Corporation, Kashiwa, Japan) with two wavelengths of near-infrared light (695 and 830 nm). Optical data based on the modified Beer-Lambert law 43 as previously described was analyzed. 44 Signals reflecting the oxygenated hemoglobin (oxy-Hb), deoxygenated hemoglobin (deoxy-Hb), and total hemoglobin (total-Hb) signal changes were computed in units of millimolar-millimeter (mM-mm).…”
Section: Fnirs Measurementsmentioning
confidence: 99%
“…20 The basis of this approach is the modified Beer-Lambert law. [21][22][23] This method is suitable for repeated measurement of cerebral perfusion at the bedside, because it is simple, noninvasive, requires minimal patient restraint, has high-temporal resolution, and is portable. 24,25 NIRS has been increasingly used in recent years in various clinical fields including neurosurgery, neurology, psychiatry, and rehabilitation.…”
Section: Introductionmentioning
confidence: 99%