Pacemakers and defibrillators: anaesthetic implications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
24
0
4

Year Published

2007
2007
2020
2020

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(28 citation statements)
references
References 49 publications
0
24
0
4
Order By: Relevance
“…Prinzipiell kann es durch Hochfrequenzchirurgie zu Hemmung und/oder Triggerung des SM-Systems, aber auch zu Änderungen des Stimulationsmodus kommen [8,9,19,24,26,50,56,60,65,70,74,84,90,100,103,105]. Eine kontinuierliche Anwendung verursacht normalerweise ein Umschalten des SM in den asynchronen "noise interference mode", während intermittierendes Kautern zu jeweils vorüberge-hender Hemmung führen kann und ungünstigstenfalls längere Pausen bis hin zur Asystolie möglich sind [86].…”
Section: Quellen Elektromagnetischer Interferenzunclassified
“…Prinzipiell kann es durch Hochfrequenzchirurgie zu Hemmung und/oder Triggerung des SM-Systems, aber auch zu Änderungen des Stimulationsmodus kommen [8,9,19,24,26,50,56,60,65,70,74,84,90,100,103,105]. Eine kontinuierliche Anwendung verursacht normalerweise ein Umschalten des SM in den asynchronen "noise interference mode", während intermittierendes Kautern zu jeweils vorüberge-hender Hemmung führen kann und ungünstigstenfalls längere Pausen bis hin zur Asystolie möglich sind [86].…”
Section: Quellen Elektromagnetischer Interferenzunclassified
“…To decrease the risk of cardiac events throughout pregnancy 18 pregnant women with LQTS should take their cardiac medications throughout the perinatal period, including labour and delivery. 2,15 Women with a cardiac pacemaker or ICD should have a review of the type and nature of the device 19 and this should be recorded on the antenatal chart. The effect of a magnet on the ICD should also be noted, whether the magnet will deactivate the defibrillator function, and whether the ICD program will be altered once the magnet is removed.…”
Section: 12mentioning
confidence: 99%
“…The effect of a magnet on the ICD should also be noted, whether the magnet will deactivate the defibrillator function, and whether the ICD program will be altered once the magnet is removed. 19,20 An ECG can be used to assess the frequency of paced beats. 2 Beta blockers are the mainstay of drug therapy in patients with LQTS with the exception of LQT3.…”
Section: 12mentioning
confidence: 99%
See 1 more Smart Citation
“…Tab. 4 soll einen Anhalt über mögliche Probleme geben, die eine Rücksprache mit dem Radiologen und/oder der Herstellerfirma über die MRT-Kompatibilität erfordern kön-nen[9,10].Herzschrittmacher und implantierte Defibrillatoren ("automatic implantable cardioverter defibrillator", AICD) sowie Cochlearimplantate sind Kontraindikation für eine Untersuchung im MRT[13]. Hier kann es zu dauernden Funktionsstö-rungen und Myokardschäden durch Erhitzung der Elektroden kommen.Derzeit werden aber im Rahmen von wissenschaftlichen Studien MRT-taugliche Schrittmacher getestet -eine Zulassung nach MPG ist bisher jedoch noch nicht erfolgt.Stents, Coils, Gefäßfilter, Aneurysmaclips und künstliche Herzklappen gelten als sicher, sofern sie aus nichtferromagnetischem Material bestehen.…”
unclassified