Packaging Effects on MEMS Pressure Sensor Hysteresis

Abstract: Micro-electro-mechanical systems (MEMS) have allowed high precision pressure sensors to be manufactured at low cost, but they typically exhibit some level of hysteresis behaviour, which is believed to be primarily due to the materials used to package them. In order to evaluate the effects of the different packaging materials and processes, in this study, the performance of piezoresistive absolute pressure MEMS was measured for each of the first two packaging stages of the product assembly process. Sensing elem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…In addition to the L1 and L2 packaging configurations, as described in Table 1, a floating L1 configuration (L1-F) was also achieved as an intermediate packaging step between the standard L0 and L1 configurations. Without being subjected to any prior thermal preconditioning, ten units were initially packaged in this L1-F configuration, following the method described by Hamid et al [39]. The sensing elements in this configuration were supported by only the wire bonds and were therefore considered to be "floating".…”
Section: Testing Sequencementioning
confidence: 99%
See 2 more Smart Citations
“…In addition to the L1 and L2 packaging configurations, as described in Table 1, a floating L1 configuration (L1-F) was also achieved as an intermediate packaging step between the standard L0 and L1 configurations. Without being subjected to any prior thermal preconditioning, ten units were initially packaged in this L1-F configuration, following the method described by Hamid et al [39]. The sensing elements in this configuration were supported by only the wire bonds and were therefore considered to be "floating".…”
Section: Testing Sequencementioning
confidence: 99%
“…The system used to temperature and pressure cycle test the different packages was identical to the one previously described by the authors [39]. The sensors were mounted to a metal manifold, as shown in Figure 3, and a Druck "PACE6000" was used to control the air pressure.…”
Section: Testing Sequencementioning
confidence: 99%
See 1 more Smart Citation