Paper-based microfluidic system for tear electrolyte analysis

Abstract: This article describes a paper-based microfluidic system that quantifies the concentrations of tear electrolytes using a smartphone-based reader.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

5
104
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 123 publications
(110 citation statements)
references
References 38 publications
5
104
0
1
Order By: Relevance
“…The fluorescence intensity increased by 7.4‐fold with increasing Ca 2+ ion concentration. The dissociation constant of the BAPTA for Ca 2+ ions was calculated to be 302 µmol L −1 (Equation ), which was comparable with the previously reported value (320 µmol L −1 ) …”
supporting
confidence: 90%
See 2 more Smart Citations
“…The fluorescence intensity increased by 7.4‐fold with increasing Ca 2+ ion concentration. The dissociation constant of the BAPTA for Ca 2+ ions was calculated to be 302 µmol L −1 (Equation ), which was comparable with the previously reported value (320 µmol L −1 ) …”
supporting
confidence: 90%
“…A potential approach to dry eye severity assessment and subtype differentiation is through the measurements of tear electrolytes, in which the composition differs based on the dry eye subtype. Sensing tear electrolytes can provide quantitative data to diagnose and track the course of dry eye syndrome, manage the eye drop medication dosage, as well as create a diagnostic basis for personalized eye drops …”
mentioning
confidence: 99%
See 1 more Smart Citation
“…[33] The stains on the chip are the preloaded indicators.When a4.8 mL droplet containing metal ions over the concentration of the ppm scale was dripped on the chip,i tw as divided into five microdroplets and reacted with the indicators in the sensing zones.T he specific colors in these sensing zones indicate the existence of Ni 2+ ,C u 2+ ,o rC r 6+ ions and the acidity of the sample.T his strategy can be extended to the multianalyte detection of biosamples,s uch as tears,b lood, and urine. [34,35]…”
Section: Resultsmentioning
confidence: 99%
“…Las desviaciones anormales de pH, además de predisponer a estas patologías, podrían afectar la respuesta terapéutica a antibióticos y la intolerancia a lentes de contacto. Por tanto, el monitoreo del pH en la práctica clínica podría ser de gran utilidad (Coles & Jaros, 1984;Pinna, Usai, Sechi, Carta, & Zanetti, 2011;Yetisen, Jiang, Tamayol, Ruiz-Esparza, & Zhang, 2017 Continuación de la tabla 5 la lágrima podría favorecer una adaptación más suave al lente, dado que la aceptación de este es más confortable en aquellos casos en que el pH es más alcalino (cercano a 8.0) (Motolko & Breslin, 1981).…”
Section: Discussionunclassified