2019
DOI: 10.1016/j.ijheatmasstransfer.2018.10.023
|View full text |Cite
|
Sign up to set email alerts
|

Parameter analysis of atomized droplets sprayed evaporation in flue gas flow

Abstract: Please check the manuscript for details of any other licences that may have been applied and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. You may not engage in further distribution of the material for any profitmaking activities or any commercial gain. You may freely distribute both the url (http://uhra.herts.ac.uk/) and the content of this paper for research or private study, educational, or not-for-profit purposes without p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 45 publications
(12 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…The Reynolds number (Re) is determined by the relative velocity between air and droplet. The drag coefficient C D can be expressed as follows in accordance with different Re [22]:…”
Section: Discrete Phasementioning
confidence: 99%
“…The Reynolds number (Re) is determined by the relative velocity between air and droplet. The drag coefficient C D can be expressed as follows in accordance with different Re [22]:…”
Section: Discrete Phasementioning
confidence: 99%
“…Further, several numerical studies have also been carried out on FDG wastewater droplet evaporation to evaluate the thermal performance, and investigate the effect of design and operating parameters (position and number of nozzles, droplet size, flue gas temperature/flow rate, spray direction, etc. [21][22][23][24]). In these studies, the droplets diameter distribution is obtained by assumption, and little or no real information is available for the validation of the numerical results.…”
Section: Introductionmentioning
confidence: 99%
“…However, the droplets evaporation is a nonlinear, multi-factor effected and complex process. Therefore, the researchers studied the spray evaporation from different perspectives by both experiment [10,[12][13][14] and numerical simulation [15][16][17][18][19][20]. Deng et al [15] investigated how the nozzle position arrangement and the flue gas temperature effected the evaporation through the computational fluid dynamic simulation methods.…”
Section: Introductionmentioning
confidence: 99%
“…A full-scale investigation of the influencing factors such as the full cone angle of the nozzle, the flue gas and atomized wastewater droplets characteristics, the interaction between the gas-liquid flow, will be analyzed. Our previous work [16]conducted single nozzle arrangement performance on parameters effected the evaporation process while in the present study the improves double-nozzle condition will be fully investigated. With the obtained numerical data, a LSSVM model is established to predict the wastewater droplets evaporation performance and optimize the influencing factors.…”
Section: Introductionmentioning