2015 Intl Aegean Conference on Electrical Machines &Amp; Power Electronics (ACEMP), 2015 Intl Conference on Optimization of Ele 2015
DOI: 10.1109/optim.2015.7426997
|View full text |Cite
|
Sign up to set email alerts
|

Parameters calculation of single- and double-cage models for induction motors from manufacturer data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…It is known that, in double-cage machines, the dimension of equations is very larger compared with the single-cage machines and this takes place since some technical relations should be considered to account for the connections between two cages in double-cage machines. However, double-cage-induction machines are studied in [23][24][25][26][27][28][29][30][31][32] as some samples. In [23,24], the modelling procedure for fault detection of outer-cage broken bar is considered approximately without including saturation and space harmonics effects.…”
Section: Research Articlementioning
confidence: 99%
See 1 more Smart Citation
“…It is known that, in double-cage machines, the dimension of equations is very larger compared with the single-cage machines and this takes place since some technical relations should be considered to account for the connections between two cages in double-cage machines. However, double-cage-induction machines are studied in [23][24][25][26][27][28][29][30][31][32] as some samples. In [23,24], the modelling procedure for fault detection of outer-cage broken bar is considered approximately without including saturation and space harmonics effects.…”
Section: Research Articlementioning
confidence: 99%
“…In [29], broken bar studying has been performed using Poisson's and Laplace's equations but the saturation effect and core permeability was neglected so time harmonics effect was not considered. In addition to fault diagnosis aim, some research have been performed for parameters estimation in double-cage-induction machines [30][31][32]. In all of mentioned references, in order to obtain the single-line diagram, the single-phase model should have been studied without non-ideal effects such as space and time harmonics.…”
Section: Research Articlementioning
confidence: 99%