Paraprotein interference with turbidimetric gentamicin assay

Abstract: IntroductionGentamicin due to its low level of resistance and rapid bactericidal activity is commonly used to treat gram-negative bacteria. However, due to its toxic effects it needs to be monitored. To date, no interference has been reported with gentamicin assays.Materials and methodsA patient with leg cellulitis and sepsis received a single dose of gentamicin and a sample was sent for gentamicin analysis. The sample showed high blank absorbance readings on Beckman DxC800 and DC800 analysers with various dil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
32
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(32 citation statements)
references
References 16 publications
0
32
0
Order By: Relevance
“…High Phenytoin Levels and Abnormal Lipemic Index others (5-10). Paraprotein interference with vancomycin, gentamycin, and valproate analyses has also been described, with falsely decreased drug levels or unreportable results flagged by the instrument (11)(12)(13). Although a spuriously low serum phenytoin level had been previously reported on the Siemens Dimension ® RxL and Vista systems (14,15), to our knowledge, this is the first case of a paraprotein causing an erroneously high phenytoin concentration.…”
Section: Case Reportsmentioning
confidence: 60%
“…High Phenytoin Levels and Abnormal Lipemic Index others (5-10). Paraprotein interference with vancomycin, gentamycin, and valproate analyses has also been described, with falsely decreased drug levels or unreportable results flagged by the instrument (11)(12)(13). Although a spuriously low serum phenytoin level had been previously reported on the Siemens Dimension ® RxL and Vista systems (14,15), to our knowledge, this is the first case of a paraprotein causing an erroneously high phenytoin concentration.…”
Section: Case Reportsmentioning
confidence: 60%
“…Polyethylene glycol (PEG) precipitation is a common, convenient, and nonspecific method used to detect and/or remove assay interference due to antibodies and other high molecular weight proteins in serum . A high vancomycin control of 38 mg/L was prepared.…”
Section: Investigations and Resultsmentioning
confidence: 99%
“…Polyethylene glycol (PEG) precipitation is a common, convenient, and nonspecific method used to detect and/or remove assay interference due to antibodies and other high molecular weight proteins in serum. 2,4,5 A high vancomycin control of 38 mg/L was prepared. The sample was divided and diluted in a 1:2 ratio with 25% PEG6000 solution (Fluka#812160, PEG6000, Sigma Aldrich, St. Louis, MO) or phosphate-buffered saline (PBS), incubated, centrifuged (10 min at 13,200 g), and the concentrations of the supernatants compared.…”
Section: Investigations and Resultsmentioning
confidence: 99%
See 2 more Smart Citations