2017
DOI: 10.1109/tie.2016.2618786
|View full text |Cite
|
Sign up to set email alerts
|

Partial Current Harmonic Compensation in Dual Three-Phase PMSMs Considering the Limited Available Voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(33 citation statements)
references
References 33 publications
0
33
0
Order By: Relevance
“…6 remains unaltered, the amplitude of the fifth and seventh current harmonics increases to 39.19% and 15.14%, respectively. Although these harmonics can be compensated by the control system, an oversized dc‐link voltage is required [13]. In order to compare both designs at rated conditions, the efficiency and the TWD of current, EMF and torque are given in Table 5.…”
Section: Fea Resultsmentioning
confidence: 99%
“…6 remains unaltered, the amplitude of the fifth and seventh current harmonics increases to 39.19% and 15.14%, respectively. Although these harmonics can be compensated by the control system, an oversized dc‐link voltage is required [13]. In order to compare both designs at rated conditions, the efficiency and the TWD of current, EMF and torque are given in Table 5.…”
Section: Fea Resultsmentioning
confidence: 99%
“…Although virtual vectors impose zero x-y voltage components over a sampling period, x -y currents with considerable magnitude may continue to circulate in the stator windings due to machine asymmetries, deadtime effects in the power switches of the VSIs or, in the case of PMSMs, the back-EMF harmonics due to the non-sinusoidal shape of PMs [117][118][119]. Since the elimination of these current harmonics requires the application of non-zero x-y voltages, the concept of dual virtual vectors was introduced in Reference [120].…”
Section: Bi-subspace Predictive Current Control Based On Virtual Vectorsmentioning
confidence: 99%
“…However, the cost will be increased, so it is always preferred to retain the conventional design of the inverter where there are only current sensors. Observers can be adopted to estimate unmeasured variables and applied as the feedback of the controllers, which has been researched in the literature [10,11,[14][15][16][17][18][19][20]. In particular, in [10,11], state observers in the rotating reference frame were presented to estimate the variables for the motor equipped with an LC filter.…”
Section: Introductionmentioning
confidence: 99%