2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289)
DOI: 10.1109/psec.2002.1022543
|View full text |Cite
|
Sign up to set email alerts
|

Partial discharge detection in power modules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
18
0

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 2 publications
0
18
0
Order By: Relevance
“…see ref. [3][4][5][6]. This paper summarizes the critical insulation defects for power modules and addresses the failure root causes.…”
Section: Introductionmentioning
confidence: 99%
“…see ref. [3][4][5][6]. This paper summarizes the critical insulation defects for power modules and addresses the failure root causes.…”
Section: Introductionmentioning
confidence: 99%
“…Despite their importance, a scanty attention is provided in ascertaining their dielectric integrity and reliability while at service. Currently practiced methods mainly focus on ensuring the dielectric breakdown strength and Partial Discharge (PD) level of an IGBT module as a factory level acceptance criterion [1,2]. Pertinent tests are used only for decision making while the potential of PD is not fully utilized [2].…”
Section: Introductionmentioning
confidence: 99%
“…Currently practiced methods mainly focus on ensuring the dielectric breakdown strength and Partial Discharge (PD) level of an IGBT module as a factory level acceptance criterion [1,2]. Pertinent tests are used only for decision making while the potential of PD is not fully utilized [2]. In this context, extensive research has been carried out and there exists at least a decade of data and literatures which has resulted in development of new materials and improvement in existing technology [3].…”
Section: Introductionmentioning
confidence: 99%
“…However, there may be untested areas of silicone gels when the module leaves the factory owing to the inability of the standard module test method to stress all parts of the silicone gel encapsulation [2]. This is due to the test being carried out with all terminals being bonded to high voltage while in operation they can, depending on the exact nature of the switch position, be at different potentials [3]. Silicone gel should not age under the presence of an electric field alone [4] but may vary in performance according to the environmental conditions.…”
Section: Introductionmentioning
confidence: 99%