“…Department of Energy Report, 1980) is the very efficient space utilization in the winding construction, comprised of: sheet conductor (aluminum foil) , polymer film insulation (Mylai>S) film) , and pressurized SF^ gas (impregnating the film-foil structure). Previous published studies (Reed andco-workers, 1980, 1981) on the 60 Hz partial discharge and breakdown performance of small model wind ings built with this construction have 1) verified the feasibility of using multiple samples wound concentrically upon one another and separated by a buffer padbreakdown had no effect upon adjacent samples -, 2) examined the effect of conduc tor edge conditioning, polymer film thickness, and gas pressure. The present report is a continuation of this work using small capacitor-like models.…”