Partial Discharge Localization Inside Transformer Windings via Fiber-Optic Acoustic Sensor Array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
33
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 69 publications
(33 citation statements)
references
References 25 publications
0
33
0
Order By: Relevance
“…The FOAS structure using polymer film has better performance due to the large radius of the polymer film, thermal stability up to 150 o C makes it suitable for the harsh environment in the transformer. The FP interferometer is limited to use only TLS for PD detection [41]- [43]. This FOAS sensor is competent to utilize both TLS and BBS as its light sources.…”
Section: Figure 8 Fft Response Of Foas Using Tls With 25 CM Apart Bmentioning
confidence: 99%
“…The FOAS structure using polymer film has better performance due to the large radius of the polymer film, thermal stability up to 150 o C makes it suitable for the harsh environment in the transformer. The FP interferometer is limited to use only TLS for PD detection [41]- [43]. This FOAS sensor is competent to utilize both TLS and BBS as its light sources.…”
Section: Figure 8 Fft Response Of Foas Using Tls With 25 CM Apart Bmentioning
confidence: 99%
“…Most power grid failures are caused by insulation defects [1]- [3]. Partial discharge (PD) usually occurs when electrical equipment is defective in insulation [4]. As the primary equipment in the power grid, the insulation status of the transformer directly affects the safe operation of the power grid [5], [6].…”
Section: Introductionmentioning
confidence: 99%
“…In [26], an improved propagation route search (IPRS) algorithm has been proposed, which can obtain the fastest propagation route of the PD signal. In [27], the acoustic wave propagation inside the transformer has been discussed, and a fiber-optic acoustic sensor array has been designed for PD localization in transformer winding. The paper [28] has studied how to locate the PD in the transformer by the macro fiber composite sensors (MFCS).…”
Section: Introductionmentioning
confidence: 99%
“…The security and reliability of the power system are closely related to the stable operation of transformers [1]. Therefore, status monitoring and fault diagnosis on transformers become research hotspots in the industry [2][3][4][5]. [6][7][8] indicate that loosing and deformation faults of transformer winding are caused by multiple impacts of short-circuit current, these factors can affect the insulation performance of winding, even cause the transformer to burn down, power failure and other major power accidents.…”
Section: Introductionmentioning
confidence: 99%