2011
DOI: 10.1109/tdei.2011.5931076
|View full text |Cite
|
Sign up to set email alerts
|

Partial discharge parameters to evaluate the insulation condition of on-line located defects in medium voltage cable networks

Abstract: Partial discharge analysis has a long record as reliable diagnostic tool to assess the integrity and the quality of electrical insulation of power systems. On-line partial discharge monitoring systems for live medium voltage cable connections have recently been introduced in Dutch grids and also a few worldwide. To enhance the applicability of on-line cable diagnostics there is a need to develop a PD interpretation approach suitable for on-line monitoring. This paper discusses various PD parameters, including … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(7 citation statements)
references
References 7 publications
0
6
0
1
Order By: Relevance
“…To improve the effectiveness of online cable prognosis, ref. [143] discusses various PD parameters and their related statistical values, such as PD charge magnitude, occurrence rate, and charge density, to interpret PD activity. The observation of the trends of these parameters is used to study the connection of the cables and the state of degradation of the components.…”
Section: New Prognostic Systems For Medium-voltage Linesmentioning
confidence: 99%
“…To improve the effectiveness of online cable prognosis, ref. [143] discusses various PD parameters and their related statistical values, such as PD charge magnitude, occurrence rate, and charge density, to interpret PD activity. The observation of the trends of these parameters is used to study the connection of the cables and the state of degradation of the components.…”
Section: New Prognostic Systems For Medium-voltage Linesmentioning
confidence: 99%
“…Banyak metode yang dapat dilakukan untuk mendeteksi adanya PD pada isolasi, salah satunya adalah deteksi PD menggunakan metode non konvensional menggunakan sensor HFCT untuk mendeteksi PD pada kabel. Hingga saat ini, aplikasi yang paling praktis dalam metode pengukuran PD pada tegangan menengah (MV) kabel jaringan hampir secara eksklusif dilakukan off-line [9]. Selain itu sebagian besar sistem pengujian hanya menguji frekuensi rendah dari partial discharge [10].…”
Section: Pendahuluanunclassified
“…Moreover, an unbalanced current in the metal sheath will limit the current-carrying capacity of the cable [1], [2]. To address the abovementioned problems, the cross interconnection of metal sheaths is adopted to reduce the circulation in the sheath and reduce the induced voltage [3], [4]. However, the cross-bonded connection design introduces new challenges to the online monitoring and diagnosis of cable insulation.…”
Section: Introductionmentioning
confidence: 99%