2001
DOI: 10.1016/s0003-4975(01)02509-7
|View full text |Cite
|
Sign up to set email alerts
|

Patient-prosthesis mismatch can be predicted at the time of operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
124
1

Year Published

2003
2003
2020
2020

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 132 publications
(126 citation statements)
references
References 7 publications
1
124
1
Order By: Relevance
“…This would also be the equivalent to the PPM levels. 3) While other studies focused on the impact of PPM on clinical outcome, the present study focused on the characteristics of the PPM patient group. Furthermore, this study revealed that the influence of characteristics on outcomes changed according to whether m-or r-EOAI was used.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This would also be the equivalent to the PPM levels. 3) While other studies focused on the impact of PPM on clinical outcome, the present study focused on the characteristics of the PPM patient group. Furthermore, this study revealed that the influence of characteristics on outcomes changed according to whether m-or r-EOAI was used.…”
Section: Discussionmentioning
confidence: 99%
“…3) Though many have reported a link between PPM after aortic valve replacement (AVR) and late left ventricular function, cardiac events or survival, some do not agree that the link exists. [4][5][6][7][8][9][10][11][12][13][14] On the other hand, the focus of attention on PPM is its occurring after AVR instead of mitral valve replacement (MVR).…”
Section: Introductionmentioning
confidence: 99%
“…The practical implications of these findings are important given that moderate-severe PPM is not a rare occurrence with a prevalence between 19 and 70% being reported in the literature. 4,12 Furthermore, as opposed to other predictors of short-term mortality, moderate-severe …”
Section: Discussionmentioning
confidence: 99%
“…In light of these recent data (66)(67)(68), every effort should be made to avoid prosthesis-patient mismatch in the patients with low-flow AS. The clinical implications of these findings are important given that prosthesis-patient mismatch is frequent (20% to 30%) after AVR and, as opposed to other risk factors, it can largely be avoided or its severity can be reduced with the use of a prospective strategy at the time of operation (36,(70)(71)(72)(73)(74).…”
Section: Management Of Patients With Ps Asmentioning
confidence: 99%