Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Introduction The introduction of the functional lumen imaging probe (FLIP) has provided objective, real-time feedback on the geometric variations with each component of a hiatal hernia repair (HHR). The utility of this technology in altering intraoperative decision-making has been scarcely reported. Herein, we report a single-center series of intraoperative FLIP during HHR. Methods A retrospective review of electronic medical records between 2020 and 2022 was conducted and all patients undergoing non-recurrent HHR with FLIP were queried. Patient and hernia characteristics, intraoperative FLIP values and changes in decision-making, as well as early post-operative outcomes were reported. Both diameter and distensibility index (DI) were measured at 40 ml and 50 ml balloon inflation after hiatal dissection, after hiatal closure, and after fundoplication when indicated. Results Thirty-three patients met inclusion criteria. Mean age was 62 ± 14 years and mean BMI was 28 ± 6 kg/m2. The majority (53%) were type I hiatal hernias. The largest drop in DI occurred after hiatal closure, with minimal change seen after fundoplication (mean DI of 4.3 ± 2. after completion of HH dissection, vs 2.7 ± 1.2 after hiatal closure and 2.3 ± 1 after fundoplication when performed). In 13 (39%) of cases, FLIP values directly impacted intraoperative decision-making. Fundoplication was deferred in 4/13 (31%) patients, the wrap was loosened in 2/13 (15%); the type of fundoplication was altered to achieve adequate anti-reflux values in 2/13 (15%) patients, and in 1/13 (3%) the wrap was tightened. Conclusion FLIP measurements can be used intraoperatively to guide decision-making and alter management plan based on objective values. Long-term outcomes and further prospective studies are required to better delineate the value of this technology.
Introduction The introduction of the functional lumen imaging probe (FLIP) has provided objective, real-time feedback on the geometric variations with each component of a hiatal hernia repair (HHR). The utility of this technology in altering intraoperative decision-making has been scarcely reported. Herein, we report a single-center series of intraoperative FLIP during HHR. Methods A retrospective review of electronic medical records between 2020 and 2022 was conducted and all patients undergoing non-recurrent HHR with FLIP were queried. Patient and hernia characteristics, intraoperative FLIP values and changes in decision-making, as well as early post-operative outcomes were reported. Both diameter and distensibility index (DI) were measured at 40 ml and 50 ml balloon inflation after hiatal dissection, after hiatal closure, and after fundoplication when indicated. Results Thirty-three patients met inclusion criteria. Mean age was 62 ± 14 years and mean BMI was 28 ± 6 kg/m2. The majority (53%) were type I hiatal hernias. The largest drop in DI occurred after hiatal closure, with minimal change seen after fundoplication (mean DI of 4.3 ± 2. after completion of HH dissection, vs 2.7 ± 1.2 after hiatal closure and 2.3 ± 1 after fundoplication when performed). In 13 (39%) of cases, FLIP values directly impacted intraoperative decision-making. Fundoplication was deferred in 4/13 (31%) patients, the wrap was loosened in 2/13 (15%); the type of fundoplication was altered to achieve adequate anti-reflux values in 2/13 (15%) patients, and in 1/13 (3%) the wrap was tightened. Conclusion FLIP measurements can be used intraoperatively to guide decision-making and alter management plan based on objective values. Long-term outcomes and further prospective studies are required to better delineate the value of this technology.
Background Laparoscopic revisional surgery for recurrent hiatal hernia (HH) is technically demanding. Re-recurrences are common and esophageal hiatus mesh reinforcement might improve durability of the repair, thus minimizing the risk of re-herniation. Purpose Assess safety and effectiveness of simple suture repair (no mesh group) vs. crural augmentation with a biosynthetic absorbable mesh (mesh group) in patients with recurrent HH. Methods Observational retrospective study from September 2012 to December 2022. Only patients undergoing redo surgery for previous failures of hiatal hernia repair were enrolled. Surgical failure was defined as symptomatic recurrent HH with > 2 cm of gastric tissue above the diaphragmatic impression at upper gastrointestinal endoscopy and/or swallow study. Gastro-Esophageal Reflux Disease Health-Related Quality of Life (GERD-HRQL) and Short Form-36 (SF-36) questionnaires were used to assess and preoperative and postoperative symptoms and quality of life. Results One hundred four patients were included. Overall, 60 patients (57.7%) underwent mesh-reinforced cruroplasty, whereas 44 (42.3%) underwent simple suture cruroplasty. Mesh and no mesh groups had similar baseline demographics, symptoms, prevalence of esophagitis and Barrett’s esophagus, and HH size. A composite crural repair was most commonly performed in the mesh group (38.3% vs. 20.5%; p = 0.07). In addition to cruroplasty, most patients (91%) underwent a Toupet fundoplication. The 90-day postoperative complication rate was 8.6%, and there was no mortality. Recurrent HH was diagnosed in 21 patients (20.2%) with a clinical trend toward reduced incidence in the mesh group (16.7% vs. 25%; p = 0.06). Compared to baseline, there was a statistically significant improvement of median GERD-HRQL score (p < 0.01) and all SF-36 items (p < 0.01). Conclusions Laparoscopic revisional surgery for recurrent HH is safe and effective. Selective use of biosynthetic mesh may protect from early recurrence and has the potential to reduce re-herniation in the long-term.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.