2016
DOI: 10.4236/ojrad.2016.64035
|View full text |Cite
|
Sign up to set email alerts
|

Patient’s Comfort and Technical Quality Exams at 1.5 and 3.0 T Magnetic Resonance Imaging

Abstract: Increased interest of clinicians for using 3.0 T magnetic resonance imaging (MRI), as imaging modality of choice for their patients, has been evident in the past few years. The aim of this study was to compare the technical quality of the obtained tomography using 3.0 T and 1.5 T MRI, and to compare the subjective feeling of discomfort of patients and subjective acoustic noise experience during imaging using MRI at 3.0 T and 1.5 T. Brain MRI (1.5 and 3.0 T) was performed in 58 patients, according to a standard… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…A higher magnetic field makes the recording more susceptible to the development of artifacts and the presence of a lack of homogeneity. [ 111 ] Also, increased patient discomfort in terms of nausea, weakness, metallic taste in the mouth, peripheral nerve stimulation, dizziness, and noise associated with sequencing (acoustic noise) has been reported with the 3.0 Tesla machine than with the 1.5 Tesla machine. [ 111 ] These observations in addition to our results indicate the superiority of the 1.5 Tesla MRI machine in DOI recording for tongue carcinomas.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A higher magnetic field makes the recording more susceptible to the development of artifacts and the presence of a lack of homogeneity. [ 111 ] Also, increased patient discomfort in terms of nausea, weakness, metallic taste in the mouth, peripheral nerve stimulation, dizziness, and noise associated with sequencing (acoustic noise) has been reported with the 3.0 Tesla machine than with the 1.5 Tesla machine. [ 111 ] These observations in addition to our results indicate the superiority of the 1.5 Tesla MRI machine in DOI recording for tongue carcinomas.…”
Section: Discussionmentioning
confidence: 99%
“…[ 111 ] Also, increased patient discomfort in terms of nausea, weakness, metallic taste in the mouth, peripheral nerve stimulation, dizziness, and noise associated with sequencing (acoustic noise) has been reported with the 3.0 Tesla machine than with the 1.5 Tesla machine. [ 111 ] These observations in addition to our results indicate the superiority of the 1.5 Tesla MRI machine in DOI recording for tongue carcinomas. Thus, the authors wish to provide a direction toward the possible differences and need for more studies focusing on this comparative aspect so that conclusive scientific evidence can be generated, and MRI can be recorded in the future with higher clinical relevance.…”
Section: Discussionmentioning
confidence: 99%