2022
DOI: 10.1007/s11517-022-02556-6
|View full text |Cite
|
Sign up to set email alerts
|

Patient-specific finite element analysis of heart failure and the impact of surgical intervention in pulmonary hypertension secondary to mitral valve disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 64 publications
0
8
0
Order By: Relevance
“…The computational cardiac biomechanics model was adapted from the Living Heart Human Project (version 2.1, Simulia, Dassault Systèmes) ( Baillargeon et al, 2014 ), previously used for biomechanical simulation studies by ( Genet et al, 2014 ; Sack et al, 2016a , b ; Genet et al, 2016 ; Sack et al, 2018b , a ; Peirlinck et al, 2018 ; Dabiri et al, 2018 ; Sahli Costabal et al, 2019 ; Dabiri et al, 2019b , a ; Peirlinck et al, 2021 ; Guan et al, 2020 ; Sack et al, 2020 ; Dabiri et al, 2020 ; Wisneski et al, 2020 ; Heidari et al, 2022 ; St. Pierre et al, 2022 ). The dynamic problem was solved in Abaqus 2020 (Simulia, Dassault Systèmes) using meshes of the LV with 160,000 linear tetrahedral elements with an average edge length of 1.8 ± 0.5 mm.…”
Section: Methodsmentioning
confidence: 99%
“…The computational cardiac biomechanics model was adapted from the Living Heart Human Project (version 2.1, Simulia, Dassault Systèmes) ( Baillargeon et al, 2014 ), previously used for biomechanical simulation studies by ( Genet et al, 2014 ; Sack et al, 2016a , b ; Genet et al, 2016 ; Sack et al, 2018b , a ; Peirlinck et al, 2018 ; Dabiri et al, 2018 ; Sahli Costabal et al, 2019 ; Dabiri et al, 2019b , a ; Peirlinck et al, 2021 ; Guan et al, 2020 ; Sack et al, 2020 ; Dabiri et al, 2020 ; Wisneski et al, 2020 ; Heidari et al, 2022 ; St. Pierre et al, 2022 ). The dynamic problem was solved in Abaqus 2020 (Simulia, Dassault Systèmes) using meshes of the LV with 160,000 linear tetrahedral elements with an average edge length of 1.8 ± 0.5 mm.…”
Section: Methodsmentioning
confidence: 99%
“…The material parameters (a, b, a f , b f , a s , b s , a fs , b fs ) were calibrated for the subject-specific anatomies and produced appropriate results for all models, as previously reported in the literature (Göktepe et al, 2011;Wang et al, 2013;Nikou et al, 2015;Genet et al, 2016;Dabiri et al, 2018;Peirlinck et al, 2019;Heidari et al, 2022). Table 4 lists the values of the eight calibrated passive material parameters for the two cases.…”
Section: Materials Parameter Estimationmentioning
confidence: 99%
“…A dynamic high-fidelity Multiphysics model of a four-chamber adult male human heart ( Figure 1 ) (Baillargeon et al 2014), developed under the SIMULIA Living Heart Project (Dassault Systèmes, SIMULIA Corp.) has previously been used to study various cardiovascular diseases (Wisneski et al 2020; St Pierre, Peirlinck, and Kuhl 2022) including heart failure (Genet et al 2016; Costabal, Choy, et al 2019), arrhythmia (Sahli Costabal, Yao, and Kuhl 2018), effects of drug on treating these diseases (Costabal, Matsuno, et al 2019), and performance analysis of several cardiovascular procedures including TAVR (Ghosh et al 2020b), mitral valve repair (Galili, White Zeira, and Marom 2022; Heidari et al 2022; Pasta et al 2022), and left ventricular assistance device (Pasta et al 2022). In this study, this digital twin of the human heart was used to explore the interaction between the TAVR prosthesis and the conduction fibers both during the TAVR procedure and across three cardiac cycles subsequent to the procedure, in order to gain deeper insights into the mechanisms underlying the development of new conduction abnormalities at varying implantation depths and in the presence of pre-existing CCAs.…”
Section: Introductionmentioning
confidence: 99%