Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Objectives: Recently, a standardized framework system for interpreting somatostatin receptor (SSTR)-targeted PET/CTs, termed SSTR-Reporting and Data System (RADS) 1.0, has been introduced providing reliable standards and criteria for SSTR-targeted imaging. We determined the interobserver reliability of SSTR-RADS for interpretation of 68 Ga-DOTATOC PET/CT scans in a multicentric, randomized setting.Methods: A set of 51 randomized 68 Ga-DOTATOC PET/CT scans was independently assessed by four blinded readers with different levels of experience (2 experienced readers (ER) and 2 inexperienced readers (IR)) trained with SSTR-RADS 1.0 criteria (based on a 5-point scale (from 1 = definitively benign to 5 = high certainty that neuroendocrine neoplasia is present)). Per scan, SSTR-RADS scores were assigned to a maximum of 5 target lesions (TL). An overall scan impression based on SSTR-RADS was indicated, and interobserver agreement rates on a TLbased, on an organ-based, and on an overall SSTR-RADS score-based level were computed.Readers were also asked to decide whether peptide receptor radionuclide therapy (PRRT) should be considered based on the assigned RADS scores.Results: Among the selected TL, 153 were chosen by at least 2 individual observers (all 4 readers selected the same TL in 58 of 153 [37.9%] instances). The interobserver agreement for SSTR-RADS scoring among identical TL was good (intraclass correlation coefficient [ICC] for 4, 3, and 2 identical TL, ≥0.73, respectively). For lymph node and liver lesions, excellent interobserver agreement rates were derived (ICC, 0.91 and 0.77, respectively). Moreover, the interobserver agreement for an overall scan impression based on SSTR-RADS was excellent (ICC, 0.88). Decision for PRRT based on SSTR-RADS also demonstrated an excellent agreement with an ICC of 0.80. No significant differences between ER and IR for an overall scan and TL-based SSTR-RADS scoring were observed (p≥0.18, respectively), thereby suggesting that SSTR-RADS seems to be readily applicable even for less experienced readers.Conclusions: SSTR-RADS-guided assessment demonstrated a high concordance rate, even among readers with different experience, supporting the adoption of SSTR-RADS for trials, clinical routine or outcome studies.
Objectives: Recently, a standardized framework system for interpreting somatostatin receptor (SSTR)-targeted PET/CTs, termed SSTR-Reporting and Data System (RADS) 1.0, has been introduced providing reliable standards and criteria for SSTR-targeted imaging. We determined the interobserver reliability of SSTR-RADS for interpretation of 68 Ga-DOTATOC PET/CT scans in a multicentric, randomized setting.Methods: A set of 51 randomized 68 Ga-DOTATOC PET/CT scans was independently assessed by four blinded readers with different levels of experience (2 experienced readers (ER) and 2 inexperienced readers (IR)) trained with SSTR-RADS 1.0 criteria (based on a 5-point scale (from 1 = definitively benign to 5 = high certainty that neuroendocrine neoplasia is present)). Per scan, SSTR-RADS scores were assigned to a maximum of 5 target lesions (TL). An overall scan impression based on SSTR-RADS was indicated, and interobserver agreement rates on a TLbased, on an organ-based, and on an overall SSTR-RADS score-based level were computed.Readers were also asked to decide whether peptide receptor radionuclide therapy (PRRT) should be considered based on the assigned RADS scores.Results: Among the selected TL, 153 were chosen by at least 2 individual observers (all 4 readers selected the same TL in 58 of 153 [37.9%] instances). The interobserver agreement for SSTR-RADS scoring among identical TL was good (intraclass correlation coefficient [ICC] for 4, 3, and 2 identical TL, ≥0.73, respectively). For lymph node and liver lesions, excellent interobserver agreement rates were derived (ICC, 0.91 and 0.77, respectively). Moreover, the interobserver agreement for an overall scan impression based on SSTR-RADS was excellent (ICC, 0.88). Decision for PRRT based on SSTR-RADS also demonstrated an excellent agreement with an ICC of 0.80. No significant differences between ER and IR for an overall scan and TL-based SSTR-RADS scoring were observed (p≥0.18, respectively), thereby suggesting that SSTR-RADS seems to be readily applicable even for less experienced readers.Conclusions: SSTR-RADS-guided assessment demonstrated a high concordance rate, even among readers with different experience, supporting the adoption of SSTR-RADS for trials, clinical routine or outcome studies.
Optimal patient management protocols for metastatic castration-resistant prostate cancer (mCRPC) are poorly defined and even further complexified with new therapy approvals, such as radiopharmaceuticals. The prostate-specific membrane antigen (PSMA)–targeted agent 177 Lu vipivotide tetraxetan ([ 177 Lu]Lu-PSMA-617), approved after the phase III VISION study, presents physicians with additional aspects of patient management, including specific adverse event (AE) monitoring and management, as well as radiation safety. Drawing on our experience as VISION study investigators, here we provide guidance on best practices for delivering PSMA-targeted radiopharmaceutical therapy (RPT) to patients with mCRPC. After a comprehensive review of published evidence and guidelines on RPT management in prostate cancer, we identified educational gaps in managing the radiation safety and AEs associated with [ 177 Lu]Lu-PSMA-617. Our results showed that providing sufficient education on AEs (e.g., fatigue and dry mouth) and radiation safety principles is key to effective delivery and management of patient expectations. Patient counseling by health care professionals, across disciplines, is a cornerstone of optimal patient management during PSMA-targeted RPT. Multidisciplinary collaboration is crucial, and physicians must adhere to radiation safety protocols and counsel patients on radiation safety considerations. Treatment with [ 177 Lu]Lu-PSMA-617 is generally well tolerated; however, additional interventions may be required, such as dosing modification, medications, or transfusions. Urinary incontinence can be challenging in the context of radiation safety. Multidisciplinary collaboration between medical oncologists and nuclear medicine teams ensures that patients are monitored and managed safely and efficiently. In clinical practice, the benefit-to-risk ratio should always be evaluated on a case-by-case basis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.