2022
DOI: 10.1016/j.eprac.2022.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Pediatric Continuous Reference Intervals of Serum Insulin-like Growth Factor 1 Levels in a Healthy Chinese Children Population – Based on PRINCE Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Serum IGF-1 concentration was detected using an IMMULITE2000 IGF-1 kit (L2KGF2, Siemens, UK), following the manufacturer's instructions (19). IGF-I standard deviation scores were calculated using the laboratory reference data for a survey of normal children (20). The CNP-22 ELISA kit (Cat.…”
Section: Determination Of Serum Igf-1 and Nt Pro-cnp Concentrationsmentioning
confidence: 99%
“…Serum IGF-1 concentration was detected using an IMMULITE2000 IGF-1 kit (L2KGF2, Siemens, UK), following the manufacturer's instructions (19). IGF-I standard deviation scores were calculated using the laboratory reference data for a survey of normal children (20). The CNP-22 ELISA kit (Cat.…”
Section: Determination Of Serum Igf-1 and Nt Pro-cnp Concentrationsmentioning
confidence: 99%
“…The serum IGF-1 level was tested among the non-rhGH treatment and rhGH treatment group before rhGH therapy, at 26 weeks and 52 weeks post-initiation of therapy. Additionally, the IGF-1 z-score was calculated by utilizing age- and sex-specific growth curves derived from Cao B’s paper [ 18 ]. Linear regression that OAHI was not correlated with IGF-1 z-score after the non-rhGH treatment and rhGH treatment ( F = 1.65, p = 0.20) (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Serum levels of IGF-1 and insulin-like growth factor binding protein 3 (IGFBP-3) were measured using routine laboratory assays (IMMULITE® 2000 immunoassay system (SIEMENS, Germany)). The z-score of IGF-1 was calculated using age- and sex-specific growth curves established in a previous study conducted by Cao et al [ 18 ].…”
Section: Methodsmentioning
confidence: 99%
“…Reference ranges for the laboratory parameters are listed in Additional le 1: Table S1. Values of serum AKP, phosphorus, UA, IGF-1 and height were converted to the standard deviation score (SDS) due to different reference values based on age and sex [20][21][22][23][24][25].…”
Section: Methodsmentioning
confidence: 99%