2009
DOI: 10.1016/j.polymer.2008.12.019
|View full text |Cite
|
Sign up to set email alerts
|

PEG-based hydrogel membrane coatings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

14
114
0
4

Year Published

2010
2010
2021
2021

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 119 publications
(132 citation statements)
references
References 34 publications
14
114
0
4
Order By: Relevance
“…Subsequently, no melting transition was observed, suggesting a lack of crystalline phases thus preventing the xerogel from melting. This phenomenon has previously been observed for other photopolymerised acrylate xerogels [35,40,41]. When incorporating PPG into the hydrogel, the T g value decreased as shown in Fig.…”
Section: Differential Scanning Calorimetrysupporting
confidence: 83%
See 1 more Smart Citation
“…Subsequently, no melting transition was observed, suggesting a lack of crystalline phases thus preventing the xerogel from melting. This phenomenon has previously been observed for other photopolymerised acrylate xerogels [35,40,41]. When incorporating PPG into the hydrogel, the T g value decreased as shown in Fig.…”
Section: Differential Scanning Calorimetrysupporting
confidence: 83%
“…ATR-FTIR confirmed that the surface solution was, in fact, low-molecular weight polymer. Previous studies have reported similar behaviour for other acrylates [38][39][40].…”
Section: Gel Fraction Measurementsupporting
confidence: 75%
“…The presence of abundant oxethyl groups in the PEG molecule that are capable of forming hydrogen bonds with water makes PEG a highly water-soluble material. PEG is also a nontoxic, nonimmunogenic, and amphipathic polymer, and it possesses a variety of properties pertinent to biomedical and biotechnical applications [18][19][20] . Thus, adding PEG to A. pernyi SF solutions was selected as a method for reducing gelation time in this study.…”
Section: Introductionmentioning
confidence: 99%
“…The IR spectra are normalized to the peak at 1726 cm −1 , corresponding to the acrylic carbonyl group; these carbonyl groups are largely unaffected during curing and their IR intensities should remain fixed. In contrast, the terminal CH=CH 2 bonds on the PEGDA monomers produce a peak at 1410 cm −1 [17][18][19][20]. A decrease in the intensity of the 1410 cm −1 peak when the sample is exposed to UV light indicates curing.…”
Section: Resultsmentioning
confidence: 99%