2013
DOI: 10.1002/elan.201300374
|View full text |Cite
|
Sign up to set email alerts
|

Pencil‐Drawn Dual Electrode Detectors to Discriminate Between Analytes Comigrating on Paper‐Based Fluidic Devices but Undergoing Electrochemical Processes with Different Reversibility

Abstract: A simple method is described to discriminate between analytes comigrating under on‐plate separation conditions, whose electrochemical behavior displays different reversible characters. It is based on the use of dual electrode detectors pencil‐drawn at the end of paper‐based fluidic channels defined by hydrophobic barriers. Simultaneous detection of comigrating species is achieved by applying to the upstream pencil‐drawn working electrode a potential for the oxidation (or reduction) of both analytes, while to t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
41
0
3

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 72 publications
(47 citation statements)
references
References 44 publications
3
41
0
3
Order By: Relevance
“…Considering the manual processing for manufacturing ePADs, the achieved RSD is acceptable and demonstrates that the proposed approach exhibits high reproducibility. It is important to highlight that the RSD values achieved in this current study are lower than most reports associated with ePADs created with graphite pencil . The low RSD values can be associated with the use of a polyester mold for defining the electrode area, which ensures better reproducibility.…”
Section: Resultsmentioning
confidence: 61%
“…Considering the manual processing for manufacturing ePADs, the achieved RSD is acceptable and demonstrates that the proposed approach exhibits high reproducibility. It is important to highlight that the RSD values achieved in this current study are lower than most reports associated with ePADs created with graphite pencil . The low RSD values can be associated with the use of a polyester mold for defining the electrode area, which ensures better reproducibility.…”
Section: Resultsmentioning
confidence: 61%
“…Hydrogen peroxide formed during the enzymatic reaction of glucose resulted in the oxidation of 4-aminophenylboronic acid to 4-aminophenol which was determined voltammetrically at the Pencil drawn electrode (PDE). Dossi et al [17] have also explored the electrochemical behaviour of ascorbic acid, dopamine and paracetamol by cyclic voltammetry at their PDEs and have reported well-defined redox behaviour. Thin-layer chromatography was used to separate mixtures of these compounds and co-eluting species could be identified using a dual electrode redox system formed from two in series PDEs.…”
Section: Introductionmentioning
confidence: 99%
“…Algumas das vantagens do dispositivo proposto é o baixo custo do papel sulfite utilizado como substrato, como previamente mencionado, sem necessidade de um processo de isolamento com um polímero sobre a face de trás do dispositivo para evitar perda de solução durante as medições [47,48,134], além de que não foi observado deformações do papel quando molhado pelo líquido durante as análises como observado com os dispositivos feitos com papel cromatografico. A Tabela 5 apresenta uma comparação entre os substratos, eletrodos, materiais e instrumentação necessária para a fabricação de alguns dispositivos baseados em papel relatados na literatura.…”
Section: Resultsunclassified
“…Podem ainda ser confeccionados os eletrodos usando métodos mais sofisticados como a deposição metálica por sputtering [42,43]. Para uso de eletrodos carbonáceos, além do uso de tinta condutiva, há trabalhos que fazem o uso do grafite [44,45] e da pintura direta no papel com minas de grafite [46][47][48]. Uma abordagem alternativa é o uso de fios metálicos fixados sobre a superfície do substrato de papel [49,50].…”
Section:  Análises Químicas Tradicionais De Drogas De Abusounclassified
See 1 more Smart Citation