2019
DOI: 10.28989/avitec.v1i1.497
|View full text |Cite
|
Sign up to set email alerts
|

Pendeteksi Tingkat Kebisingan berbasis Internet of Things sebagai Media Kontrol Kenyamanan Ruangan Perpustakaan

Abstract: The library is a place that is used as a study and reading room, so that a comfortable place is needed from disturbances in the library building. Based on the decision of the Minister of Environment in 1996, the standard noise for library environments ranged from 45 to 55 dB. but in fact there is often a commotion caused by visitors. in this study a noise level detection system was created where the noise detection system is expected to be used as a media for comfort control in the library room. The noise leve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0
4

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 0 publications
0
4
0
4
Order By: Relevance
“…According to research conducted by Nurjannah et al (2017) using the KY-037 microphone sensor, the sensor capability ranges from 31-110 dB, which is consistent with our study. Hidayat et al (2019) used a condenser microphone sensor to measure sound pressure levels in a minimum range of 41 dB and a maximum of 69 dB with an average error value of 1.0%. Although the error percentage of our instrument is larger than Hidayat et al (2019), the measurement range of ours is more comprehensive than that of Hidayat et al (2019).…”
Section: Testing Of Measuring Instruments With Digital Sound Level Me...mentioning
confidence: 99%
See 1 more Smart Citation
“…According to research conducted by Nurjannah et al (2017) using the KY-037 microphone sensor, the sensor capability ranges from 31-110 dB, which is consistent with our study. Hidayat et al (2019) used a condenser microphone sensor to measure sound pressure levels in a minimum range of 41 dB and a maximum of 69 dB with an average error value of 1.0%. Although the error percentage of our instrument is larger than Hidayat et al (2019), the measurement range of ours is more comprehensive than that of Hidayat et al (2019).…”
Section: Testing Of Measuring Instruments With Digital Sound Level Me...mentioning
confidence: 99%
“…Hidayat et al (2019) used a condenser microphone sensor to measure sound pressure levels in a minimum range of 41 dB and a maximum of 69 dB with an average error value of 1.0%. Although the error percentage of our instrument is larger than Hidayat et al (2019), the measurement range of ours is more comprehensive than that of Hidayat et al (2019).…”
Section: Testing Of Measuring Instruments With Digital Sound Level Me...mentioning
confidence: 99%
“…Ke 5 adalah alat yang dibuat oleh Saftiadi, A. Asni B dan Aswadul Fitri Saiful Rahman "Perancangan Sistem Kontroler Alat Elektronik Rumah Tangga Berbasis Mikrokontroler Arduino Uno Dengan Perintah Suara". Mikrokontroler Aduino Uno yang digunakan sebagai pengntrol kerja alat yang dimana alat ini menggunakan perangkat android sebagai penerima perintah suara [9].…”
Section: Penelitian Terdahuluunclassified
“…http://ejournal.urindo.ac.id/index.php/TI Pengukuran tingkat suara kerap digunakan terkait Keselamatan Kesehatan Keamanan Kerja (K3) [8]. Adapun pengukuran tingkat suara saat ini lebih menitikberatkan pada pengukuran tingkat suara pada lingkungan maupun kawasan [2] yang memiliki standar berbeda bila dibandingan dengan K3.…”
Section: Pendahuluanunclassified